PAGE
12
www.allfett.net
INTEGRATED CONTROL CARD DESCRIPTIONS
Alarms listed below are shown on PROGRAM DISPLAY. While alarm is occured PROGRAM DISPLAY
will be indicating. Also while alarm is occured warn led will continýously flashing.
CONTROL CARD PANEL
Electrical socket
INTEGRATED CONROL CARD COMPONENTS
Integrated control card is optional. Not presented onto standard ALL-1 pumps.
Kontrol
panel
Assembly
screws,
(M4 - imbus)
Control panel
cover
Control panel cover
screws
Motor connection cables
Sigorta
HOUR
MINUTE
SECOND
WAIT.
LUB.
WARN.
SERVICE
ADD. CYCLE
PROGRAM DISPLAY
CONTROL CARD ALARM LIST
A4 : Fuse broken
This alarm is shown if fuse broken.
A3 : Motor alarm
This alarm is shown if motor
cabels are broken or motor fault.
A2 : Pressure alarm
This alarm is shown if adjusted
pressure reached.
A1 : Low level alarm
This alarm is shown if pump
out of grease.
WAIT.
: Yellow LED (Waiting)
LUB.
: Green LED (Lubricating)
WARN.
: Red LED (Warning, Fault)
SERVICE
: Using to start programming.
ADDITIONAL CYCLE
:
Using to lubricate only one time
except the programmed working time. And also using
to change numbers while programming.
PROGRAM DISPLAY
: This led shows programming
numbers.
HOUR
: Shows unit of time.
MINUTE
: Shows unit of time.
SECOND
: Shows unit of time.
Содержание ALL-1 PS
Страница 23: ...PAGE 22 www allfett net NOTES ...