SAFETY INFORMATION

 

DO NOT connect the bare or green insulation fixture ground wire to the black (HOT) current-carrying 

wire or the white (NEUTRAL)  house wire. Connection of the bare or green fixture ground wire to the 
black or white house wires may cause metal parts of the fixture to carry electrical currents. Under this 
condition anyone coming in contact with the fixture will receive electrical shock, which could cause 
serious injury or death.

 

DO NOT damage or cut the wire insulation (covering) during installation of fixture. DO NOT permit 

wires to contact any surface having a sharp edge. To do so may damage or cut the wire insulation, 
which could cause serious injury or death from electrical shock.

 

All electrical connections must be in agreement with local codes and ordinances, the National Electric 

Code (NEC) and ANSI/NFPA 70-1999. Contact your municipal building department to learn about 
your local codes, permits and/or inspections. 

Risk of 

fire - most dwellings built before 1985 have 

supply wire rated for 140°F. Consult a qualified electrician before installation.

 

To avoid personal injury, the use of gloves may be necessary while handling fixture parts with sharp 

edges.

 

DO NOT suspend any fixture by the house wires. A fixture must always be mounted directly to an 

outlet box or to a mounting plate which is first attached to the outlet box. Wire connectors will not 
support the weight of a fixture. Suspending a fixture by the house wires and wire connectors will 
result in the fixture falling, with the possibility of personal injury and the danger of electrical shock or 
fire.

 

To reduce the risk of fire, electrical shock or personal injury, wire connectors provided with this 

light 

fixture are designed to accept only one 12-gauge house wire and two lead wires from the light fixture. 
If your house wire is larger than 12-gauge or there is more than one house wire to connect to th

corresponding fix

ture lead wires, consult an electrician for the proper size wire connectors to use.

 Note

This equipment has been tested and found to comply with the limits for a Class B digital 

device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable 
protection against harmful interference in a residential installation. This equipment generates, uses 
and can radiate radio frequency energy and, if not installed and used in accordance with the 
instructions, may cause harmful interference to radio communications. However, there is no 
guarantee that interference will not occur in a particular installation. If this equipment does cause 
harmful interference to radio or television reception, which can be determined by turning the 
equipment off and on, the user is encouraged to try to correct the interference by one or more of the 
following measures:  - Reorient or relocate the receiving antenna. - Increase the separation between 
the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to 
which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.

 

TURN OFF ELECTRICITY at main fuse box (or circuit breaker box) before beginning installation by 

removing the fuse (or switching the circuit breaker off).

 

If you are not sure the lighting system has a grounding means, DO NOT attempt to install this fixture. 

Contact a qualified, licensed electrician for information regarding the proper grounding methods as 
required by the local electrical code in your area.

 

All fixtures must be mounted to an outlet box that is supported by the building structure.

 

If a dimmer control switch is used with this fixture, obtain professional advice to determine the 

correct type to use as well as the electrical rating required.

 

Do NOT tamper with or attempt to repair LED component of fixture. The light source is designed for 

this specific application and should not be serviced by untrained personnel. If any servicing is 
required, call our customer service department. 

WARNING

CAUTION

NOTE:

 Dimmable to 10% with select dimmers. See Lowes.com for more information.

Содержание VBL2-18GD

Страница 1: ...ts Before returning to your retailer call our customer service department at 1 866 439 9800 8 a m 6 p m EST Monday Thursday 8 a m 5 p m EST Friday 1 Purchase Date ATTACH YOUR RECEIPT HERE welcoming so...

Страница 2: ...efore attempting to assemble install or operate this product Failure to do so could lead to fire electrical shock or other injuries that could be hazardous or even fatal DO NOT connect this fixture to...

Страница 3: ...wires consult an electrician for the proper size wire connectors to use Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the...

Страница 4: ...ng assembly of product make sure all parts are present Compare parts with package contents list and hardware contents list If any part is missing or damaged do not attempt to assemble the product Esti...

Страница 5: ...lastic outlet boxes are not recommended 4 5 Hardware Used Machine Screw x 2 BB 4 A Pilot Hole DD Determine the approximate location for the fixture A Place mounting plate B against the wall and mark t...

Страница 6: ...power supply wires WARNING To reduce the risk of fire electrical shock or personal injury wire connectors AA are designed to accept only one 12 gauge house wire and two lead wires from the light fixt...

Страница 7: ...f necessary Restore power and test fixture A If lights do not function please refer to TROUBLESHOOTING 9 If you wish to use your fixture with the side plates F provided remove the decorative nuts D Us...

Страница 8: ...ccidental damage or improper handling and or installation and specifically excludes liability for direct incidental or consequential damages improper packaging of returned products and acts of God As...

Отзывы: