Publication 1734-UM005B-EN-P - June 2001
6-2
Troubleshooting the PROFIBUS Adapter
Indicator
Indication
Probable Cause
System Power
Off
Not active.
Field power is off; or dc-dc converter problem.
Green
System power on.
Dc-dc converter active (5V).
Field Power
Off
Not active.
Field power not applied.
Green
Power on, 24V present.
Adapter Status
Off
No power supplied.
Hardware check in progress.
Initialization in progress.
Green
Adapter operating normally
Red
Hardware check fault.
PROFIBUS Status
Off
No power supplied.
Adapter is off-line (no data exchange with the
PROFIBUS master).
Green
Adapter is online (data exchange with the PROFIBUS
master).
Flashing Green
Adapter is in CLEAR mode and has set the connected
I/O modules into an idle state.
Red
No POINT I/O modules installed in the backplane.
Flashing Red
Set_Parameter telegram rejected.
Maximum number of user parameter bytes overridden.
PointBus Status
Off
No power applied to adapter
PointBus initialization in progress.
Green
Normal operation.
Flashing Red
Incorrect POINT I/O module installed or
POINT I/O module removed from backplane.
Red
Critical link failure. Adapter detected error that
prevents its communication on the PointBus.
Содержание POINT I/O PROFIBUS 1734-APB
Страница 1: ...POINT I O PROFIBUS Adapter Module Cat No 1734 APB User Manual Allen Bradley HMIs...
Страница 6: ...Publication 1734 UM005B EN P June 2001 Preface 4...
Страница 24: ...Publication 1734 UM005B EN P June 2001 2 10 Installing the PROFIBUS Adapter...
Страница 62: ...Publication 1734 UM005B EN P June 2001 6 4 Troubleshooting the PROFIBUS Adapter...
Страница 82: ...Publication 1734 UM005B EN P June 2001 B 18 Default Data Maps...
Страница 84: ...Publication 1734 UM005B EN P June 2001 2...
Страница 87: ...Allen Bradley HMIs...