Publication 1734-UM005B-EN-P - June 2001
Installing the PROFIBUS Adapter
2-7
After the 14th (or last) module, you must insert an expansion
power supply (cat. no. 1734-EP24DC) to power additional I/O
modules.
Refer to the table below for various POINT I/O modules current
requirements.
For more information on the Expansion Power Supply, cat. no.
1734-EP24DC, refer to:
•
POINT I/O Technical Data, publication 1734-TD001A
•
POINT I/O Expansion Power Supply Installation Instructions,
publication 1734-IN058A
POINT I/O Cat. No.
PointBus Current
Requirements
1734-IB2
1734-IB4
1734-IV2
1734-IV4
1734-OB2E
1734-OB4E
1734-OW2
1734-IE2C
1734-OE2C
1734-IE2V
1734-OE2V
1734-IA2
1734-IM2
1734-OA2
1734-IJ2
1734-IK2
1734-IR2
1734-IT2
1734-VHSC5
1734-VHSC24
75mA
75mA
75mA
75mA
75mA
75mA
80mA
75mA
75mA
75mA
75mA
75mA
75mA
75mA
160mA
160mA
220mA
175mA
180mA
180mA