ATTENTION: 

This equipment is intended for use in a Pollution Degree 2 industrial 

environment, in overvoltage Category II applications (as defined in EN/IEC 60664-1), 
at altitudes up to 2000 m (6562 ft) without derating.

This equipment is not intended for use in residential environments and may not 
provide adequate protection to radio communication services in such environments.

This equipment is supplied as open-type equipment for indoor use. It must be 
mounted within an enclosure that is suitably designed for those specific 
environmental conditions that will be present and appropriately designed to 
prevent personal injury resulting from accessibility to live parts. The enclosure 
must have suitable flame-retardant properties to prevent or minimize the spread 
of flame, complying with a flame spread rating of 5V A or be approved for the 
application if nonmetallic. The interior of the enclosure must be accessible only by 
the use of a tool. Subsequent sections of this publication may contain more 
information regarding specific enclosure type ratings that are required to comply 
with certain product safety certifications.

In addition to this publication, see the following:

• Industrial Automation Wiring and Grounding Guidelines, 

publication 

1770-4.1

, for additional installation requirements.

• NEMA Standard 250 and EN/IEC 60529, as applicable, for explanations of the 

degrees of protection provided by enclosures.

ATTENTION: 

Read this document and the documents listed in the Additional 

Resources section about installation, configuration, and operation of this 
equipment before you install, configure, operate, or maintain this product. Users 
are required to familiarize themselves with installation and wiring instructions in 
addition to requirements of all applicable codes, laws, and standards.

Installation, adjustments, putting into service, use, assembly, disassembly, and 
maintenance are required to be carried out by suitably trained personnel in 
accordance with applicable code of practice. In case of malfunction or damage, no 
attempts at repair should be made. The module should be returned to the 
manufacturer for repair. Do not dismantle the module.

Содержание POINT I/O 1734-4IOL

Страница 1: ...nformation 2 Environment and Enclosure 3 Prevent Electrostatic Discharge 4 Special Conditions for Safe Use 5 About the Module 6 Install the Mounting Base 9 Install the Module 9 Install the RemovableTe...

Страница 2: ...with any particular installation Rockwell Automation Inc cannot assume responsibility orliability for actual use based on the examples and diagrams No patent liability is assumed by Rockwell Automatio...

Страница 3: ...by the use of a tool Subsequent sections of this publication may contain more information regardingspecific enclosure type ratings that are required to comply with certain product safety certification...

Страница 4: ...an approved grounding wriststrap Do not touch connectors or pins on component boards Do not touch circuit components inside the equipment Use a static safe workstation if available Store the equipment...

Страница 5: ...nd anchors appropriately Be sure to ground the DIN rail properly Refer to Industrial AutomationWiring and Grounding Guidelines publication1770 4 1 for more information Do not remove or replace an Adap...

Страница 6: ...pplication In IO Link mode the module supports four channels for IO Link master communication with IO Link compatible devices In standard digital I O mode the module supports four channels of digital...

Страница 7: ...s 3 Insertable I O module 8 Mechanical keying orange 4 Removable terminal block RTB handle 9 DIN rail locking screw orange 5 Removable terminal block 10 Module wiring diagram Analog Voltage Output Mod...

Страница 8: ...inal Base Description Description 1 Module locking mechanism 6 Interlocking side pieces 2 Slide in writable label 7 Mechanical keying orange 3 Insertable I O module 8 DIN rail locking screw orange 4 T...

Страница 9: ...locking side pieces to engage the adjacent module or adapter 3 Press firmly to seat the mounting base on the DIN rail The mounting base snaps into place Be sure that the orange DIN rail locking screw...

Страница 10: ...nstalled aligns with the notch in the base 2 Make certain the DIN rail locking screw is in the horizontal position You cannot insert the module if the locking mechanism is unlocked 3 Insert the module...

Страница 11: ...opposite the handle into the base unit This end has a curved section that engages with the wiring base 2 Rotate the terminal block into the wiring base until it locks itself in place WARNING Whenyouco...

Страница 12: ...to place on the module WARNING For 1734 RTBS and 1734 RTB3S to latch and unlatch the wire insert a bladed screwdriver catalog number 1492 N90 3 mm diameter blade into theopeningatapproximately73 blade...

Страница 13: ...nal block 3 Press the module lock on the top of the module 4 Pull on the I O module to remove from the base 5 Repeat steps 1 2 3 and 4 for the module to the right 6 Use a small bladed screwdriver to r...

Страница 14: ...Link Master Module 1734 4IOL POINT I O 4 Channel IO Link Master ModuleWiring IO Link Mode Channel Common Voltage 0 4 6 1 5 7 2 4 6 3 5 7 Power is supplied through the internal power bus 1734 4IOL Cha...

Страница 15: ...Channel Input Common Voltage Channel 0 0 4 6 Channel 1 1 5 7 Channel 2 2 4 6 Channel 3 3 5 7 Connect common on 3 wire inputs Power is supplied through the internal power bus Channel Output Common Vol...

Страница 16: ...Default Data Map for 1734 4IOL Configuration Assembly Instance 100 Message Size 46 Bytes Consumed Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 36 Channel 0 fault mode 1 37 Channel 0 idle mode...

Страница 17: ...b Output data for Channel 1 1 b 1 c Output data for Channel 2 1 c 1 d Output data for Channel 3 1 1 Consumed sizes can be in the range of 0 32 Output data for each channel always begin on a 32 bit bou...

Страница 18: ...rcuit Bit 6 1 Process data invalid Bit 7 1 Low power fault Bit 8 1 IO Link output value is forced to limit Bit 9 15 Reserved 2 Produced sizes can be in the range of 0 32 Input data for each channel al...

Страница 19: ...line and has connections in the established state Flashing red One or more I O connections are in timed out state Red Critical link failure failed communication device Device detected error that preve...

Страница 20: ...C Thermal dissipation max 5 12 BTU hr 28 8V DC Isolation voltage 50V continuous basic insulation type Tested at 2121V DC for 60 s field side to system No isolation between individual channels Field po...

Страница 21: ...I O 4 Channel IO Link Master Module 1734 4IOL Standard Digital Input Attribute Value Backplane power 5V DC 100 mA Input ratings 24V DC 12 mA On state voltage min 11V DC On state current min 2 0 mA On...

Страница 22: ...20 55 C 4 131 F Temperature nonoperating IEC 60068 2 1 Test Ab unpackaged nonoperating cold IEC 60068 2 2 Test Bb unpackaged nonoperating dry heat IEC 60068 2 14 Test Na unpackaged nonoperating therm...

Страница 23: ...Control Equipment certified for US and Canada See UL File E322657 CE European Union 2014 30 EU EMC Directive compliant with EN 61326 1 Measurement Control Laboratory use Industrial requirements EN 61...

Страница 24: ...24 Rockwell Automation Publication 1734 IN043B EN E January 2019 POINT I O 4 Channel IO Link Master Module Notes...

Страница 25: ...Rockwell Automation Publication 1734 IN043B EN E January 2019 25 POINT I O 4 Channel IO Link Master Module Notes...

Страница 26: ...26 Rockwell Automation Publication 1734 IN043B EN E January 2019 POINT I O 4 Channel IO Link Master Module Notes...

Страница 27: ...t User Forums and Product Notification Updates www rockwellautomation com knowledgebase LocalTechnical Support Phone Numbers Locate the phone number for your country www rockwellautomation com global...

Страница 28: ...Otomasyon Ticaret A Kar Plaza Merkezi E Blok Kat 6 34752 erenk y stanbul Tel 90 216 5698400 Rockwell Automation maintains current product environmental information on its website at http www rockwella...

Отзывы: