Rockwell Automation Publication 2711P-UM006A-EN-P - November 2010
Chapter 6
Install and Replace Components
2.
If the display module is removed from the panel, set the terminal,
display-side down, on a clean, flat, stable surface.
3.
Position the communication module over the logic module so that the
connector on the bottom of the module aligns with the connector on the
logic module.
4.
To prevent ESD between the modules, allow the communication module
to touch the logic module before making the connection.
5.
Push down on the communication module until the connectors are seated.
6.
Tighten the four screws that secure the communication module to the
logic module to a torque of 0.58 N•m (5…7 lb•in).
COMM
FAULT
DEFAUL
T
RESET
Connector for
Communication Module
Communication Module
Connector
Logic Module
Attached
Communication Module