Allen-Bradley MSR42 Скачать руководство пользователя страница 6

4   

Light Curtain Multi-Function Control Module User Manual

Or

i

g

i

nal 

i

nstruct

i

ons

Status out

p

uts

The MSR42 base module has two status outputs (“Info1” and “Info2”). 
The logic of these two outputs depends on the configuration. A 
description of these outputs is given in the configuration control 
document. The following table shows the logic of the two status outputs 
for the basic configuration. The state of the status outputs will also be 
displayed through LED, visible on the front side of the main module.

Table 1

LED d

i

s

p

lay ele

m

ents

Table 2 gives information about the LED on the front side of a MSR42 
control unit with the basic configuration:

Table 2

Res

p

onse t

im

e

General

The response time of a MSR42 main module depends on the 
configuration.

The relevant maximum response times for the MSR42 control module, 
with respect to a specific Micro 400 light curtain and MSR45E expander 
module, as well as a specific safety component may be calculated using 
the formulas below. 

The response time may be increased if a stop delay time t(delay) is 
configured for a safety component or a Micro 400 light curtain. During 
this delay, all start impulses are ignored. The safety outputs will switch 
off at the end of this delay period. 

The controller is shipped with the double scan filter. Single scan filter can 
be selected to reduce the response time. The relevant times may be found 
in the corresponding configuration control document (e.g. see 
configuration software manual).

If authorized personnel reconfigure the 
control module using the USB/optical 
interface, then depending on the 
configuration the response time or the 
stop delay time t(delay) may increase. So 
it is very important that after every new 
configuration. 
a. the configuration change label 

(page 13) is placed on the control 
module and

b. the new response time is confirmed to 

be within the limits given by the risk 
analysis of the machine and

c. All relevant data of the actual 

configuration are always described in 
the actual configuration control 
document for that controller. Make 
sure that the actual document is 
always stored near to the control unit.

d. Using the blanking mode, the 

resolution of the Micro 400 will be 
reduced. Label the Micro 400 with the 
new resolution. A label is supplied 
with the Micro 400 light curtain 
mounting kit.

Terminal (LED)

Output "high" (+24 V)

Output "low" (0 V)

Info1 (LED)

Start ok (green)

No  start possible (red)

Info2 (LED)

System okay (green)

Error (Lock out) (red)

These outputs may not perform any 
safety relevant functions. They are 
diagnostic outputs which provide status 
to a machine controller.

LED

Signal / Color /Status

Signal / Color /Status

Lamp

Orange / muting or blanking 
activated

Off / muting or blanking not 
activated

GPIO4

+24 V / green / automatic 
start

0 V / off / manual start

GPIO3

+24 V / green / manual start 
signal high or automatic start

0 V / off / manual start

GPIO2

+24 V / green / Teach-in 
Blanking active

0 V / off / Teach-in Blanking 
inactive

GPIO1

+24 V / green / Teach-in 
Blanking active

0 V / off / Teach-in  Blanking 
inactive

OSSD2

+24 V / green / Micro 400 not 
Activated

0 V / red / Micro 400 activated 
(e.g. interrupted)

OSSD1

+24 V / green / Micro 400 not 
Activated

0 V / red / Micro 400 activated 
(e.g. interrupted)

Info2 (LED)

See page 4

See page 4

Info1 (LED)

See page 4

See page 4

IN2

+24 V / green / start release 
okay

0 V / red / no start release 
signal

IN 1

+24 V / green / no test

0 V / red / test

0 V

-

-

+24 V

+24 V / green / power 
connected

0 V / off / no power 
connected

Terminology

t(C)

Response time for the MSR42 control module (evaluation time), 
without light curtain evaluation time

t(LC)

Response time of the light curtain

t(delay)

Stop delay time for the outputs

t(em)

Response time for the MSR45E expansion module

t(GPIO)

Evaluation time for the safety component (GPIO filter time)

t(SCext)

Response time of the external safety component (e.g. Safe4)

t(totLCOSSD)

Maximum OSSD response time triggered by the light curtain

t(totLCEXT)

Maximum relay extension module response time for the light curtain

t(totSCOSSD)

Maximum OSSD response time for the safety components on GPIO

Содержание MSR42

Страница 1: ...MSR42 Control Module User Manual...

Страница 2: ...GI 1 1 Safety Guidelines for the Application Installation and Maintenance of Solid State Control available from your local Rockwell Automation sales office describes some important differences between...

Страница 3: ...nd GmbH are available online at www ab com The actual list of relevant safety data and applied standards is given in these documents Introduction The MSR4x is a family of extremely compact safety cont...

Страница 4: ...light curtain Figure 16 Applications Typical applications Typical MSR42 base module applications are Presses Robotic cells with automatic insertion Assembly lines Indexing tables Conveyor systems Auto...

Страница 5: ...ustomer Configurations The configuration of a MSR42 control module is set up via of the USB optical interface and the Allen Bradley GuardShield Software Configuration Diagnostic Tool The configuration...

Страница 6: ...and c All relevant data of the actual configuration are always described in the actual configuration control document for that controller Make sure that the actual document is always stored near to t...

Страница 7: ...SD t em Basic configuration The maximum controller response time t C for the MSR42 control module is given in chapter 14 However depending from the connected Micro 400 light curtain the response time...

Страница 8: ...e of a very short safety light curtain interruption the safety outputs will stay low Relays open for 80ms at minimum A start signal will only be recognized after the 80ms duration EDM or start release...

Страница 9: ...if e g the protective field is interrupted Figure9 ConnectingaSafetyOverridekeyswitchandtheassociatedlamp Depending on the risk evaluation when using a Safety override key operated switch a correspond...

Страница 10: ...wo types of blanking available through the MSR42 Fixed blanking Floating blanking When blanking is activated this has to be clearly indicated by a display or a lamp The MSR42 has only one monitored ou...

Страница 11: ...he double scan mode in the Micro 400 window of the MSR42 Configuration Diagnostic Tool software see Double Scan Filter in Software Configuration Tool Manual Testing the MSR42 standard Blanking area Fi...

Страница 12: ...aults apply to the Out of Box configurations only Reference Table 15 for detailed information Table15 The lock out mode of a MSR42 control module may be reset by one of two methods 1 Power down then P...

Страница 13: ...40R P226AGS NNR Relay Input Voltage Reset Outputs Cat No MSR45E Safety Relay Expansion Module SuppliedbyMSR41 or MSR42 Determined by MSR41 or MSR42 2 N O 440 P4NANS Part number Description 440R ACABL1...

Страница 14: ...y HW Hardware Version SafetyLevel Cat Safetycategory according to EN ISO 13849 1 SafetyLevel SIL Safety integrity level according to EN 61508 SafetyLevel PL Performance level acc to EN ISO 13849 1 Pow...

Страница 15: ...t UN coded Maximum cable length for safety switches 50 m out and back total 100 m See page 6 or 10 Safety Prevention Lamp Minimum current at Lamp 0 9 A with lamp switched on GPIO1 GPIO4 Outputs to saf...

Страница 16: ...ro 400 Evaluation time t EvalLC see label light curtain only important for interrupt ignore time Controller response time t C 14 70 ms Stop delay time t delay 0 00 ms Interrupt ignore time t ignore 0...

Страница 17: ...2004 A1 2008 Safety of machinery Electro sensitive protective equipment Part 1 General requirements and tests IEC 61496 2 2006 Safety of machinery Electro sensitive protective equipment Part 2 Particu...

Страница 18: ...221AGS MSR41 base module 440R P226AGS NNR MSR42 base module 445L 104794 B MSR42 base module customer configuration 440R P4NANS MSR45E expander module 445L 1 MSR45E expander module customer configurati...

Страница 19: ...hi toimuda enne kui installeerija on omandanud koopia tootja instruktsioonidega keeles mida ta ise valdab Instruktsioonid erinvates keeltes on saadaval siin http rockwellautomation com literature SUOM...

Страница 20: ...aan Boulevard du Souverain 36 1170 Brussels Belgium Tel 32 2 663 0600 Fax 32 2 663 0640 Asia Pacific Rockwell Automation Level 14 Core F Cyberport 3 100 Cyberport Road Hong Kong Tel 852 2887 4788 Fax...

Отзывы: