Allen-Bradley MSR42 Скачать руководство пользователя страница 14

12   

Light Curtain Multi-Function Control Module User Manual

Or

i

g

i

nal 

i

nstruct

i

ons

I

ns

p

ect

i

on and serv

i

ce

The MSR42 control modules are built electronically and do not need 
preventive maintenance.

I

ns

p

ect

i

ons

The MSR42 control modules have to be tested periodically – in 
accordance with valid regulations - by qualified and trained personnel to 
discover prohibited manipulations or unauthorized modifications.

Deco

mmi

ss

i

on

i

ng

The MSR42 modules can only be removed, when the machine or the 
equipment is shut down completely and can no longer be operated 
without tools. If a controller has to be disposed, it can be simply 
dismantled. The separated materials can be recycled according to state of 
the art technology and corresponding regulations of the country it was 
used in.

Product labels

All the necessary safety information can be found on the product labels 
and the Configuration Control Label, which can be found on each 
controller module (example):

Figure 14: Product label MSR42 control module

Table 18

All of the configuration information will also be found on the 
configuration control document, which is included with the delivery of 
each MSR42 control module.

Note:

In the event that a MSR42 control module is reconfigured by authorized 
personnel using the USB/optical interface, a new Configuration Control 
Label must be filled out and applied next to the existing label (Figure 15). 
Details of the new configuration are given in the configuration control 
document.

Figure 15: The new special configuration identification "Configuration changed" must be 
positioned next to the existing label.

Techn

i

cal Data

Explanation of terminology

HW

Hardware Version

Safety Level Cat.

Safety category according to EN ISO 13849-1

Safety Level SIL

Safety integrity level according to EN 61508

Safety Level PL

Performance level acc. to EN ISO 13849-1

Power class

Power supply

Temperature range

Operating temperature range

OSSD

Max. current available per OSSD output, at the listed voltage

General data

Nominal working mode

Continuous process

Temperature range

Environment temp.: 0 ... +55°C
Stock temp.: -25 ... +70°C

Enclosure rating according EN 60529
Housing
Terminals

IP20
IP20

Conductor connection:
4-, 5-pin, terminal strip (plug-in)

Wire cross section: 
1 x max 2.5 mm

2

  (14 AWG) stranded

spring clamping technology

Quick mounting

Top hat rail 35 mm (EN 50022)

Net weight

130 g (0.287 lbs)

Housing dimensions

111 x 22,5 x 125 mm (incl. plugs) See page 2

Housing material

Polyamide

Vibration according to EN60068-2-6

Amplitude: 0.35 mm
Frequency: 10 … 55 Hz

Shock resistant according to EN 60068-2-29

Acceleration: 100 ms

-2

Impulse length: 16 ms
Number of shocks: 1'000 per direction

Mounting

35 mm DIN Rail

Approvals

TÜV, CE, cULus

Interfaces

Optical (OptiLink)

Weight and packaging

Dispatch packaging

280 mm x 200 mm x 70 mm

Dispatch weight

Net  220 g

Power Supply

Input Power Entry

+24 VDC (EN 60204-1) See page 4

Max. power consumption at max. supply voltage

2.1 W (semiconductor outputs unloaded)

at 5 % residual ripple

0.85 ... 1.15 U

N

Current consumption

Current max. 70 mA + 70 mA per relay extension 
module (semi conductor outputs unloaded) 
maximal: 1.7 A depending on  attached load

Controller protection (external)

5 A slow

Inputs

Safety inputs (software configurable)

(1 x 2 NC or 2x 2 OSSD) and 1 Micro 400

Reset mode

Automatic / Manual or Manual monitored

Control current into:
IN 1, IN 2

2 mA each (min.) (in accordance with EN 61131-2)

Minimum voltage at: 
IN 1, IN 2

11 VDC at activated controller (EN 61131-2)

Содержание MSR42

Страница 1: ...MSR42 Control Module User Manual...

Страница 2: ...GI 1 1 Safety Guidelines for the Application Installation and Maintenance of Solid State Control available from your local Rockwell Automation sales office describes some important differences between...

Страница 3: ...nd GmbH are available online at www ab com The actual list of relevant safety data and applied standards is given in these documents Introduction The MSR4x is a family of extremely compact safety cont...

Страница 4: ...light curtain Figure 16 Applications Typical applications Typical MSR42 base module applications are Presses Robotic cells with automatic insertion Assembly lines Indexing tables Conveyor systems Auto...

Страница 5: ...ustomer Configurations The configuration of a MSR42 control module is set up via of the USB optical interface and the Allen Bradley GuardShield Software Configuration Diagnostic Tool The configuration...

Страница 6: ...and c All relevant data of the actual configuration are always described in the actual configuration control document for that controller Make sure that the actual document is always stored near to t...

Страница 7: ...SD t em Basic configuration The maximum controller response time t C for the MSR42 control module is given in chapter 14 However depending from the connected Micro 400 light curtain the response time...

Страница 8: ...e of a very short safety light curtain interruption the safety outputs will stay low Relays open for 80ms at minimum A start signal will only be recognized after the 80ms duration EDM or start release...

Страница 9: ...if e g the protective field is interrupted Figure9 ConnectingaSafetyOverridekeyswitchandtheassociatedlamp Depending on the risk evaluation when using a Safety override key operated switch a correspond...

Страница 10: ...wo types of blanking available through the MSR42 Fixed blanking Floating blanking When blanking is activated this has to be clearly indicated by a display or a lamp The MSR42 has only one monitored ou...

Страница 11: ...he double scan mode in the Micro 400 window of the MSR42 Configuration Diagnostic Tool software see Double Scan Filter in Software Configuration Tool Manual Testing the MSR42 standard Blanking area Fi...

Страница 12: ...aults apply to the Out of Box configurations only Reference Table 15 for detailed information Table15 The lock out mode of a MSR42 control module may be reset by one of two methods 1 Power down then P...

Страница 13: ...40R P226AGS NNR Relay Input Voltage Reset Outputs Cat No MSR45E Safety Relay Expansion Module SuppliedbyMSR41 or MSR42 Determined by MSR41 or MSR42 2 N O 440 P4NANS Part number Description 440R ACABL1...

Страница 14: ...y HW Hardware Version SafetyLevel Cat Safetycategory according to EN ISO 13849 1 SafetyLevel SIL Safety integrity level according to EN 61508 SafetyLevel PL Performance level acc to EN ISO 13849 1 Pow...

Страница 15: ...t UN coded Maximum cable length for safety switches 50 m out and back total 100 m See page 6 or 10 Safety Prevention Lamp Minimum current at Lamp 0 9 A with lamp switched on GPIO1 GPIO4 Outputs to saf...

Страница 16: ...ro 400 Evaluation time t EvalLC see label light curtain only important for interrupt ignore time Controller response time t C 14 70 ms Stop delay time t delay 0 00 ms Interrupt ignore time t ignore 0...

Страница 17: ...2004 A1 2008 Safety of machinery Electro sensitive protective equipment Part 1 General requirements and tests IEC 61496 2 2006 Safety of machinery Electro sensitive protective equipment Part 2 Particu...

Страница 18: ...221AGS MSR41 base module 440R P226AGS NNR MSR42 base module 445L 104794 B MSR42 base module customer configuration 440R P4NANS MSR45E expander module 445L 1 MSR45E expander module customer configurati...

Страница 19: ...hi toimuda enne kui installeerija on omandanud koopia tootja instruktsioonidega keeles mida ta ise valdab Instruktsioonid erinvates keeltes on saadaval siin http rockwellautomation com literature SUOM...

Страница 20: ...aan Boulevard du Souverain 36 1170 Brussels Belgium Tel 32 2 663 0600 Fax 32 2 663 0640 Asia Pacific Rockwell Automation Level 14 Core F Cyberport 3 100 Cyberport Road Hong Kong Tel 852 2887 4788 Fax...

Отзывы: