90
Rockwell Automation Publication 2097-UM001D-EN-P - November 2012
Chapter 5
MotionView Software Configuration
Table 40 - General Category
for Linear Motors
ID
Parameter Name
Description
Value/Notes
30
(1)
Current Limit
Continuous RMS current for motor selected
User may lower this value. This lets you trigger a motor current alarm. However,
the drive will not limit the actual current to the motor. The actual RMS current
limit to the motor is not configurable.
32
(1)
8 kHz Peak Current Limit
Peak current limit for 8 kHz operation (based on
motor selected)
User may lower this peak value to limit current to motor. Do not set below the
RMS Current for motor (tag #30).
39
Motor Temperature Sensor
Motor thermal protection function
0 = Disable
1 = Enable
75
(2)
Enable Accel/Decel Limits
Enable Accel/Decel function/limits for Velocity
mode
0 = Disable
1 = Enable
76
(2)
Accel Limit
Accel value for Velocity mode
Range: 0.1…5,000,000 m/s
2
77
(2)
Decel Limit
Decel value for Velocity mode
Range: 0.1…5,000,000 m/s
2
78
Fault Reset
Reset fault configuration
Manual Only
On Disable
79
Master
Master to system ratio (numerator)
Master counts range: -32767…+32767
80
System
Master to system ratio (denominator)
System counts range: 1…32767
266
Drive Mode
Sets the mode of operation for the drive
0 = Auto Tune
1 = EtherNet/IP External Reference
2 = Master Gearing
3= Step and Direction
4 = Analog Velocity Input
5 = Analog Current Input
6 = Indexing
672
Current Output Clamp
Value to clamp output current, measured in
percentage of motor rated current
Range: 0…400%
676
User Units Scaling
Shows how many user units in one Measure unit
Range: 1…1000000
678
Measure Units
Measure units
0 = μm
1 = m
2 = in.
8
Negative Motion Polarity
Inverts the motion polarity
0 = Unchecked =Normal
1 = Checked =Reverse
Step and Direction and Gear based modes and position based moves, such as
incremental, absolute, as well as velocity based jogs obey the motion polarity.
Current based operating modes do not obey the motion polarity. The drive must
be disabled to change the motion polarity.
(1) By default, these values are set based on the configured motor. If these values are set lower than the motor capabilities, the drive will report CurrentLimitStatus in the EtherNet/IP
Input assembly at the new value, but will not clamp the current output until it reaches the motor peak current.
(2) These values apply only if the drive is in Velocity mode over EtherNet/IP External Reference. In Indexing mode, the limits within the individual indexes apply. In Positioning mode,
over EtherNet/IP External Reference, the limits in the Output Assembly apply.
Содержание Kinetix 300
Страница 4: ...4 Rockwell Automation Publication 2097 UM001D EN P November 2012 Summary of Changes Notes...
Страница 18: ...18 Rockwell Automation Publication 2097 UM001D EN P November 2012 Chapter 1 Start Notes...
Страница 188: ...188 Rockwell Automation Publication 2097 UM001D EN P November 2012 Appendix A Interconnect Diagrams Notes...
Страница 216: ...216 Rockwell Automation Publication 2097 UM001D EN P November 2012 Appendix D MicroLogix Explicit Messaging Notes...
Страница 229: ...Kinetix 300 EtherNet IP Indexing Servo Drives User Manual...
Страница 230: ......