Rockwell Automation Publication 2097-UM001D-EN-P - November 2012
85
MotionView Software Configuration
Chapter 5
Synchronous Motor Database
For Allen-Bradley synchronous motors and actuators with incremental encoders,
click Change Motor and choose the device from the Synchronous>Motor
Database. In this example, the MPL-B320P-H motor is configured.
Table 37 - Motor Category
ID
Parameter Name
Description
Value/Notes
10
Motor ID
Motor serial number (for Rockwell Automation motor)
11
Motor Model
Motor catalog number (for Rockwell Automation motor)
12
Motor Vendor
Rockwell Automation
14
Halls Order
Hallcode index
Range: 0…5
18
Jm
Motor moment of inertia
Range: 0…0.1 Kg-m
2
19
Ke
Motor voltage or back EMF constant
Range: 1…500V/K rpm
20
Kt
Motor torque or force constant
Range: 0.01…10 N•m/A
21
Lm
Motor phase-to-phase inductance
Range: 0.1…500 mH
22
Rm
Motor phase-to-phase resistance
Range: 0.01…500
Ω
23
Nominal Phase Current
Motor max current (RMS)
Range: 0.5…50 A
24
Maximum Velocity
Motor max velocity
Range: 500…20,000 rpm
25
Number Of Poles
Motor number of poles
Range: 2…200
26
PPR Before Quad
Encoder resolution
Range: 256 to (65536 x12/Npoles) expressed in PPR
27
Nominal Drive Bus Voltage
Nominal motor terminal voltage
Range: 50…800V
646
Rt
Thermal resistance
Range: 0…10000000 C/W
647
Ct
Thermal capacitance
Range: 0…10000000 W-s/C
Содержание Kinetix 300
Страница 4: ...4 Rockwell Automation Publication 2097 UM001D EN P November 2012 Summary of Changes Notes...
Страница 18: ...18 Rockwell Automation Publication 2097 UM001D EN P November 2012 Chapter 1 Start Notes...
Страница 188: ...188 Rockwell Automation Publication 2097 UM001D EN P November 2012 Appendix A Interconnect Diagrams Notes...
Страница 216: ...216 Rockwell Automation Publication 2097 UM001D EN P November 2012 Appendix D MicroLogix Explicit Messaging Notes...
Страница 229: ...Kinetix 300 EtherNet IP Indexing Servo Drives User Manual...
Страница 230: ......