6
Guardmaster® EtherNet/IP™ Network Interface
Publication 440R-IN078A-EN-P - January 2014
Before You Begin
To effectively use the interface, note the following considerations.
Determine Compatibility
RSLogix 5000™ software version 19, or greater, must be used for the 440R-ENETR
Add-on Profile. The 440R-ENETR EtherNet/IP network interface can be used with
the following Guardmaster safety relays with version 2 (or greater) firmware:
•
440R-D22R2, GSR DI
•
440R-D22S2, GSR DIS
•
440R-EM4R2, GSR EM
•
440R-EM4R2D, GSR EMD
•
440R-GL2S2P, GSR GLP
•
440R-GL2S2T, GSR GLT
If you use the BootP/DHCP utility to assign IP addresses to the interface module,
use version 2.3.2 or greater.
Install the Interface
Follow this procedure to install the interface on the DIN rail.
ATTENTION:
You must only use firmware version 2 (or greater) of
optical bus-enabled Guardmaster safety relays with the 440R-ENETR
EtherNet/IP network interface. Early versions of the firmware or
Guardmaster safety relays not equipped with an embedded optical
communication bus will not work.
Fir
m
ware Version