    Guardmaster® EtherNet/IP™ Network Interface 

Publication 440R-IN078A-EN-P - January 2014

Important User Information

Solid-state equipment has operational characteristics differing from those of 
electromechanical equipment. Safety Guidelines for the Application, Installation and 
Maintenance of Solid State Controls (publication 

SGI-IN001_-EN-P

 available from your local 

Rockwell Automation sales office or online at 

http://www.rockwellautomation.com/literature/

) describes some important differences 

between solid-state equipment and hard-wired electromechanical devices. Because of this 
difference, and also because of the wide variety of uses for solid-state equipment, all 
persons responsible for applying this equipment must satisfy themselves that each 
intended application of this equipment is acceptable.

In no event will Rockwell Automation, Inc. be responsible or liable for indirect or 
consequential damages resulting from the use or application of this equipment.

The examples and diagrams in this manual are included solely for illustrative purposes. 
Because of the many variables and requirements associated with any particular installation, 
Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on 
the examples and diagrams.

No patent liability is assumed by Rockwell Automation, Inc. with respect to use of 
information, circuits, equipment, or software described in this manual.

Reproduction of the contents of this manual, in whole or in part, without written permission 
of Rockwell Automation, Inc., is prohibited.

Throughout this manual, when necessary, we use notes to make you aware of safety 
considerations.

Identifies information about practices or circumstances that can cause an 
explosion in a hazardous environment, which may lead to personal injury or 
death, property damage, or economic loss.

Identifies information about practices or circumstances that can lead to 
personal injury or death, property damage, or economic loss. Attentions 
help you identify a hazard, avoid a hazard and recognize the consequences.

Labels may be on or inside the equipment (for example, drive or motor) to 
alert people that dangerous voltage may be present.

Labels may be on or inside the equipment (for example, drive or motor) to 
alert people that surfaces may reach dangerous temperatures.

IMPORTANT

Identifies information that is critical for successful application and 
understanding of the product.

Содержание Guardmaster EtherNet/IP 440R-ENETR

Страница 1: ...ic Page Important User Information 2 Environment and Enclosure 3 Preventing Electrostatic Discharge 4 About the Interface 5 Before You Begin 6 Determine Compatibility 6 Install the Interface 6 Set the...

Страница 2: ...ciated with any particular installation Rockwell Automation Inc cannot assume responsibility or liability for actual use based on the examples and diagrams No patent liability is assumed by Rockwell A...

Страница 3: ...esigned to prevent personal injury resulting from accessibility to live parts The enclosure must have suitable flame retardant properties to prevent or minimize the spread of flame complying with a fl...

Страница 4: ...these guidelines when you handle this equipment Touch a grounded object to discharge potential static Wear an approved grounding wrist strap Do not touch connectors or pins on component boards Do not...

Страница 5: ...s interface is designed for the Guardmaster safety relay optical bus that provides connectivity to an EtherNet IP network with two RJ 45 connectors for two port pass through to support daisy chain or...

Страница 6: ...are 440R D22R2 GSR DI 440R D22S2 GSR DIS 440R EM4R2 GSR EM 440R EM4R2D GSR EMD 440R GL2S2P GSR GLP 440R GL2S2T GSR GLT If you use the BootP DHCP utility to assign IP addresses to the interface module...

Страница 7: ...Interface on a DIN Rail Install the interface to the left of Guardmaster safety relays equipped with an optical communications bus There must be no more than 5 mm horizontal separation between two ad...

Страница 8: ...Press down firmly to install the interface on a DIN rail 3 Set the network address rotary switches to the desired value See page 9 Set the Network Address for more information on setting the IP addres...

Страница 9: ...etwork address by using the three rotary switches on the front bezel of the interface Use a small flat blade screwdriver to rotate the switches Line up the arrow on the switch with the number setting...

Страница 10: ...Address Rotary Switches Refer to publication Guardmaster 440R UM009 EtherNet IP Network Interface User Manual for more information If you set the switches to an invalid number for example 000 or a va...

Страница 11: ...as shown in the following illustration WARNING When you change switch settings while power is on an electrical arc can occur This could cause an explosion in hazardous location installations Be sure...

Страница 12: ...eat the interface on the DIN rail until the module locks into position 7 Set the network address on the network address rotary switches 8 Insert the removable terminal block into the interface 9 Recon...

Страница 13: ...ith the CE Low Voltage Directive LVD this equipment must be powered from a Safety Extra Low Voltage SELV or Protected Extra Low Voltage PELV compliant source WARNING If you connect or disconnect wirin...

Страница 14: ...Indicator Status for Interface Module Indicator Status Description Module Status Off No power applied to device Flashing green Device needs commissioning due to missing incomplete or incorrect configu...

Страница 15: ...rdmaster safety relay failure and controller operation Solid red Duplicate IP address detected Verify IP address setting and correct as needed Link 1 or Link 2 Status Off No link established Solid gre...

Страница 16: ...2 GSR EMD Catalog number 440R EM4R2D GSR GLP Catalog number 440R GL2S2P GSR GLT Catalog number 440R GL2S2T Location Left side of the Guardmaster Safety Relay system Power Supply Attribute Value Input...

Страница 17: ...89 x 4 47 in Enclosure type rating None open style Terminal base screw torque 0 8 Nm 7 lb in Weight approx 180 g 0 4 lb Wiring category 1 1 on power ports 1 on communications ports Wire size Power co...

Страница 18: ...ed Damp Heat 5 95 non condensing Vibration IEC 60068 2 6 Test Fc Operating 5 g 10 500 Hz Shock operating IEC60068 2 27 Test Ea Unpackaged Shock 15 g Emissions CISPR 11 Group 1 Class A ESD immunity IEC...

Страница 19: ...2004 108 EC EMC Directive compliant with EN 61326 1 Meas Control Lab Industrial Requirements EN 61000 6 2 Industrial Immunity EN 61000 6 4 Industrial Emissions EN 61131 2 Programmable Controllers Clau...

Страница 20: ...24 hours of installation please review the information provided in this manual You can also contact a special Customer Support number for initial help in getting your product up and running New Produ...

Отзывы: