
7–3
Calibrating Your Incremental Encoder Module
Publication 1794-6.5.15 – December 1998
Calibration Method 2
Calibration is enabled by input G if GateControl = 3 and Calibrated
= 0. The preset value is copied to the counter register at a positive
edge on input signal Z. The old counter register value is saved in the
store register for evalution.
Calibration direction is determined by CalDirection (0 = positive
direction, 1 = negative direction).
Reset Calibrated, Stored and PresetReached after calibration with
CalReset, StoreReset and PresetReset.
Counter Register
Stored Register
Counter Register
Logic
Z
Preset Register
PresetReached = 1
Stored = 1
CalDirection = Direction
of the latest count pulse
Calibrated = 0
StoreControl = 0
Stored = 0
Calibrated = 1
Logic
G = 1
GateControl = 3
Z
Содержание FLEX I/O 1794-ID2
Страница 6: ...Using This Manual P 4 Publication 1794 6 5 15 December 1998 ...
Страница 10: ...Table of Contents iv Publication 1794 6 5 15 December 1998 ...
Страница 20: ...1 10 Overview of the Incremental Encoder Module Publication 1794 6 5 15 December 1998 ...
Страница 74: ...7 4 Calibrating Your Incremental Encoder Module Publication 1794 6 5 15 December 1998 ...