COMPACT 5000 Analog 8-channel Current/Voltage Input Module

IEC Hazardous Location Approval

The following applies to products with IECEx certification: Such modules:

• Are intended for use in areas in which explosive atmospheres caused by gases, vapors, mists, or air are unlikely to occur, or are likely to occur only infrequently and for short periods. Such locations 

correspond to Zone 2 classification to IEC 60079-0.

• The type of protection is  "Ex nA IIC T4 Gc" according to IEC 60079-15.
• The 5069-IF8 module complies to standards IEC 60079-0:6th Edition, IEC-60079-15:4th Edition, reference IECEx certificate number IECEx UL 15.0055X.

Special Conditions for Safe Use

WARNING: 

• This equipment is not resistant to sunlight or other sources of UV radiation.
• This equipment shall be mounted in an ATEX/IECEx Zone 2 certified enclosure with a minimum ingress protection rating of at least IP54 (as defined in 

EN/IEC 60529) and used in an environment of not more than Pollution Degree 2 (as defined in EN/IEC 60664-1) when applied in Zone 2 environments. The 
enclosure must be accessible only by the use of a tool.

• This equipment shall be used within its specified ratings defined by Rockwell Automation.
• Provision shall be made to prevent the rated voltage from being exceeded by transient disturbances of more than 140% of the rated voltage when applied in 

Zone 2 environments.

• The instructions in the user manual shall be observed.
• This equipment must be used only with ATEX/IECEx certified Rockwell Automation backplanes.
• Secure any external connections that mate to this equipment by using screws, sliding latches, threaded connectors, or other means provided with this 

product.

• Do not disconnect equipment unless power has been removed or the area is known to be nonhazardous.
• Earthing is accomplished through mounting of modules on rail.
• Devices shall be used in an environment of not more than Pollution Degree 2.

Prevent Electrostatic Discharge

ATTENTION: 

This equipment is sensitive to electrostatic discharge, which can cause internal damage and affect normal operation. Follow these guidelines when 

you handle this equipment:

• Touch a grounded object to discharge potential static.
• Wear an approved grounding wriststrap.
• Do not touch connectors or pins on component boards.
• Do not touch circuit components inside the equipment.
• Use a static-safe workstation, if available.
• Store the equipment in appropriate static-safe packaging when not in use.

Electrical Safety Considerations

ATTENTION: 

• Do not wire more than 1 conductor on any single RTB terminal.
• In case of malfunction or damage, no attempts at repair should be made. The module should be returned to the manufacturer for repair. Do not dismantle 

the module. 

• This equipment is certified for use only within the surrounding air temperature range of 0…60 °C (32…140 °F) The equipment must not be used outside of 

this range.

• Use only a soft dry anti-static cloth to wipe down equipment. Do not use any cleaning agents.

IMPORTANT

Any illustrations, charts, sample programs, and layout examples shown in this publication are intended solely for the purposes of example. Since there are 
many variables and requirements associated with any particular installation, Rockwell Automation does not assume responsibility or liability for actual use 
based upon the examples shown in this publication.

Содержание Compact 5000

Страница 1: ...ng polled For more information on how to use Compact 5000 I O modules see the publications that are listed in Additional Resources on page 14 SummaryofChanges The following changes were made to this r...

Страница 2: ...ttuare interventi di manutenzione su di esso leggere il presente documento ed i documenti elencati nella sezione Altre risorse riguardanti l installazione la configurazione ed il funzionamento dell ap...

Страница 3: ...Les produits marqu s CL I DIV 2 GP A B C D ne conviennent qu une utilisation en environnements de Classe I Division 2 Groupes A B C D dangereux et non dangereux Chaque produit est livr avec des marqu...

Страница 4: ...y external connections that mate to this equipment by using screws sliding latches threaded connectors or other means provided with this product Do not disconnect equipment unless power has been remov...

Страница 5: ...g Piece Bottom Interlocking Piece DIN Rail Latch RTB Handle RTB MOD Power Bus and SA Power Bus Connectors isolatedfromeach other internally RTB LowerTab Lower hook for use with cable tie Component Des...

Страница 6: ...in the system that is the controller or the adapter establishes an SA power bus A system can have more than one SA power bus You use 5069 FPD field potential distributors to establish a new SA power...

Страница 7: ...p and clicks ATTENTION To reduce susceptibility to noise power analog modules and digital modules from separate power supplies IMPORTANT Werecommendthatyouuseseparateexternalpowersupplies for MOD powe...

Страница 8: ...the fronts of both modules are flush with each other InstalltheEndCap You must install an end cap on the last module in your system 1 Align the end cap with the interlocking pieces on the module 2 Pus...

Страница 9: ...sulation from the wires Spring Strip 10 mm 0 39 in of insulation from the wires RTBType Action Screw 1 Insert the wire into the terminal 2 Turn the screwdriver to close the terminal on the wire Torque...

Страница 10: ...1 Input 1 Input 2 Input 2 Input 3 Input 3 Input 4 Input 4 Input 5 Input 5 Input 6 Input 6 Input 7 Input 7 Shield Shield 2 wire Transmitter 24V DC Shield Ground A A i IMPORTANT Place additional loop d...

Страница 11: ...ge mode ANALOG INPUT 5069 IF8 Input 0 Input 0 Input 1 Input 1 Input 2 Input 2 Input 3 Input 3 Input 4 Input 4 Input 5 Input 5 Input 6 Input 6 Input 7 Input 7 Shield Shield User Analog Input Device 24V...

Страница 12: ...ces of SA power are turned off 2 If necessary remove the end cap from the right side of the module 3 If desired disconnect wires from the RTB as described on page 9 4 Press the DIN rail latch down unt...

Страница 13: ...Passthrough 2 2 Maximum level of SA Power current that the module can pass through to the next module in the system The specific level of current passed through varies based on system configuration 9...

Страница 14: ...nd EtherNet IP adapters Compact 5000 I O Analog Modules User Manual publication 5000 UM005 Describes how to use the Compact 5000 I O analog modules EtherNet IP Communication Modules in Logix 5000 Cont...

Страница 15: ...Rockwell Automation Publication 5069 IN010B EN P November 2017 15 COMPACT 5000 Analog 8 channel Current Voltage Input Module Notes...

Страница 16: ...ur documentation needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at http literature rockwellautomation com idc groups literature documents d...

Отзывы: