Chapter 2
Configure and Startup
Configure General Parameters
These are the general parameters available for the module.
The following table shows the general parameters available for the module.
ATTENTION:
When QuickConnect is enabled, you must notify the module
before you switch the module ON (inhibit instruction) or OFF (uninhibit
instruction). A hard disconnect during operation is not permitted. See the
EtherNet/IP QuickConnect Application Technique, publication
more information.
Table 4 - QuickConnect Values
Bit
MSB
LSB
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Word 32
—
QuickConnect
Where 0 = Disabled (default); 1 = Enabled
Table 5 - General Parameters
Parameter
Description
WebServerDisable
Enables or disables the web server.
0 = Enable (default), 1 = Disable
OutputGroupPowerFaultEn
Enables or disables the output group power fault reporting.
0 = Disable (default), 1 = Enable
OutputGroupFaultEn
Enables or disables the output group fault when actuator power supply is unavailable.
0 = Disable (default), 1 = Enable
DOAutoRestartEn
Enables or disables the digital out auto restart.
0 = Disable (default), 1 = Enable
RES
Reserved. Default value is 0.
Table 6 - General Parameters
Bit
MSB
LSB
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Word 32
RES DOAut
oResta
rtEn
RES RES Output
GroupF
aultEn
Output
GroupP
owerFa
ultEn
WebSe
rverDis
able
RES —