Industrial Computers for Hazardous Locations
3
Rockwell Automation Publication 6181X-IN001C-EN-P - April 2011
European Union Directive Compliance
This product meets the European Union Directive requirements when installed within the
European Union or EEA regions and have the CE mark. A copy of the Declaration of
Conformity is available at the Rockwell Automation website
under Product
Certification.
To comply with EN 55022 and EN 55024, use the following shielded or unshielded cable as
specified in this table.
Hazardous Locations
This equipment is suitable for these location categories.
ATTENTION:
To comply with EN 55022 and EN 55024, all I/O cables
must be less than 30 m (98.42 ft). These cables must not exit the
building at any point and shall not directly connect to cables outside the
building.
Cable Type
Required Attribute
LAN
Shielded or Unshielded
USB
Shielded
Serial RS-232
Shielded
DVI
Shielded
VGA
Shielded
DC Power
Unshielded
Cat. No.
Region
Class/Division/Zone Rating
Temperature
6181X-NPXPDC,
Non-display
United
States
Class I Division 2, Groups A, B, C, D T4
-20 °C
≤
T
a
≤
(-4 °F < T
a
< 158 °F)
Class I Zone 2, IIC, T4
Canada
Class I Division 2, Groups A, B, C, D T4
Class I Zone 2, IIC, T4
Europe
ATEX II 3 GD, Ex nA IIC Gc, Ex tc IIIC Dc
6181X-12TPXPDC,
Display
United
States
Class I Division 2, Groups A, B, C, D T4
-20 °C
≤
T
a
≤
55 °C
(-4 °F < T
a
< 131 °F) (Display side)
-20 °C
≤
T
a
≤
70 °C
-4 °F < T
a
< 158 °F) (Backside)
(1)
(1)
The entire 6181X-NPXPDC computer and the backside of the 6181X-12TPXPDC display are required to be mounted in a
restricted access location.
Class I Zone 2, IIC, T4
Canada
Class I Division 2, Groups A, B, C, D T4
Class I Zone 2, IIC, T4
Europe
ATEX II 3 GD, Ex nA nC IIC T4 Gc,
Ex tc IIIC T135 Dc