Sun Microsystems, Inc.
901 San Antonio Road
Palo Alto, , CA 94303-4900
U.S.A
Part No: 805-4452
September 1998, Revision A
Страница 1: ...Sun Microsystems Inc 901 San Antonio Road Palo Alto CA 94303 4900 U S A Part No 805 4452 September 1998 Revision A...
Страница 2: ...Microsystems Inc 901 San Antonio Road Palo Alto Californie 94303 Etats Unis Tous droits r serv s Ce produit ou document est prot g par un copyright et distribu avec des licences qui en restreignent l...
Страница 3: ...mory Interleaving 8 Environmental Monitoring and Control 9 Automatic System Recovery 10 Soft Deconfiguration via Status Property 10 Hard Deconfiguration 10 ASR User Override Capability 11 Auto Boot Op...
Страница 4: ...eplacing the Disk Drive In Your Application 21 UNIX File System UFS 22 Solstice DiskSuite 24 Removing a Hot Pluggable Disk Drive 27 Identifying the Faulty Disk Drive 28 Removing a Disk Drive From Your...
Страница 5: ...removing or replacing hot pluggable disk drives 4 Procedures for mapping between the logical and physical device names of internal storage devices Using UNIX Commands This document may not contain in...
Страница 6: ...n screen computer output su Password AaBbCc123 Book titles new words or terms words to be emphasized Command line variable replace with a real name or value Read Chapter 6 in the User s Guide These ar...
Страница 7: ...hnical documentation on the Web You can browse the docs sun com archive or search for a specific book title or subject at http docs sun com Sun Welcomes Your Comments You can email your comments to us...
Страница 8: ...viii September 1998 Revision A...
Страница 9: ...a 4 slot backplane To support five to twelve internal disk drives you must install an optional 8 bay storage expansion kit which includes an eight slot backplane one dual channel single ended UltraSCS...
Страница 10: ...here 4 x is an integer between 1 and 10 identifying the rear panel PCI slot number where the lower UltraSCSI controller is installed 4 y is an integer between 1 and 10 identifying the rear panel PCI s...
Страница 11: ...uilds the device trees for the system incorporating any newly installed options After a device has been added to a device tree it can be recognized by the system After the reconfiguration reboot has s...
Страница 12: ...4 September 1998 Revision A...
Страница 13: ...UPA probing 4 PCI probing 4 Memory interleaving 4 Environmental monitoring and control 4 Automatic System Recovery ASR NVRAM configuration variables covered in this chapter include 4 upa port skip lis...
Страница 14: ...om probing via the upa port skip list NVRAM variable In the following example the upa port skip list variable is used to exclude one of the UPA PCI bridges and the primary UPA graphics card from the U...
Страница 15: ...is used to define a probing order of 3 4 while excluding from the probe list the on board SCSI controller for removable media devices and the external SCSI port ok setenv pci0 probe list 3 4 The probi...
Страница 16: ...to setting for Ultra 450 systems max interleave Enables the maximum level of interleaving possible for a given memory configuration but some memory capacity remains unused if DIMMs of different capaci...
Страница 17: ...lity and Serviceability Features in the owner s guide provided with your Ultra 450 system TABLE 2 4 Settings for the env monitor Variable Setting Monitor Active Action Taken enabled default Yes In res...
Страница 18: ...without the failed component This prevents a faulty hardware component from keeping the entire system down or causing the system to crash again Soft Deconfiguration via Status Property To support a d...
Страница 19: ...interleave factor ASR User Override Capability While the default settings will properly configure or deconfigure an Ultra 450 system in most cases it is useful to provide advanced users with a manual...
Страница 20: ...abled PCI Slots Enabled Auto Boot Options OpenBoot provides for an NVRAM controlled switch called auto boot which controls whether OBP will automatically boot the operating system after each reset The...
Страница 21: ...ies with it other side effects see the OpenBoot 3 x Command Reference Manual the Ultra 450 OBP provides a new NVRAM variable called diag trigger that lets you choose which reset events if any will aut...
Страница 22: ...owing example the diag trigger variable is used to trigger POST and OpenBoot diagnostics on all resets except XIR resets ok setenv diag switch true ok setenv diag trigger soft reset 14 September 1998...
Страница 23: ...u must stop that activity before removing the drive This can be done without bringing down the operating system or powering down the system The system supports hot plugging but there are software cons...
Страница 24: ...new disk drive add the drive and then reconfigure the operating environment In all cases you must select a slot physically install the disk drive and configure the Solaris environment to recognize th...
Страница 25: ...he new drive is assigned a logical device name of the form cwtxdysz where 4 w corresponds to the SCSI controller for the disk drive 4 x corresponds to the SCSI target for the disk drive 4 y is the log...
Страница 26: ...logical device name for the new disk is c0t3d0 Configuring the New Disk Drive In Your Application Continue adding the disk by following the instructions for your specific application 4 Configuring th...
Страница 27: ...the new file system See the vfstab 4 man page for more details 5 Mount the new file system using the mount command mount mount_point where mount_point is the directory you created The file system is...
Страница 28: ...abeled and partitioned the same as the disk it will replace See the documentation for your application for instructions on how to format and partition the disk and add that disk to your application Id...
Страница 29: ...t number and the logical device name from a physical device name such as devices pci 6 4000 scsi 4 1 sd 3 0 To make the necessary translation from one form of disk identifier to another see Chapter 4...
Страница 30: ...get ID is 2 mount grep c1t2 export home1 on dev dsk c1t2d0s2 setuid read write on showmount a grep export home1 cinnamon export home1 archive austin export home1 swlab1 export home1 doc ps f grep c1t2...
Страница 31: ...unt operation may not complete A large number of error messages may be displayed in the system console and in the var directory during the umount operation If the umount operation does not complete yo...
Страница 32: ...slice for your UFS file system check and or create a file system on the slice fsck dev rdsk cwtxdysz newfs dev rdsk cwtxdysz 3 Mount the new file system using the mount command mount mount_point wher...
Страница 33: ...metastat grep c1t2d0 mount grep c1t2d0 Save the output of the commands to reconstruct the metadevice configuration after you replace the disk 5 Delete database replicas If there are database replicas...
Страница 34: ...to restart the system For each file system returned type umount filesystem where filesystem is the first field for each line returned in Step 1 on page 17 For example umount export home umount export...
Страница 35: ...deice cwtxdysz 6 Remount any file systems and restart any applications that were using metadevices that could not be taken off line mount file_system Refer to the Solstice DiskSuite documentation for...
Страница 36: ...refer to a failed disk drive by its UNIX physical device name such as devices pci 6 4000 scsi 4 1 sd 3 0 and its UNIX device instance name such as sd14 In some cases a faulty disk may be identified b...
Страница 37: ...tify activities or applications attached to the device you plan to remove Commands to use are mount showmount a and ps ef See the mount 1M showmount 1M and ps 1 man pages for more details For example...
Страница 38: ...line returned in Step 1 on page 17 For example umount export home umount export home2 Removing the Disk Drive Refer to the Sun Ultra 450 Workstation Owner s Guide or Ultra Enterprise 450 Server Owner...
Страница 39: ...ices of the disk are used by hotspare pools they can be replaced by other available slices metahs r all c1t2d0s1 c2t2d0s1 For example 7 Unmount any file systems on the disk Note If the file system s a...
Страница 40: ...Removing the Disk Drive Refer to the Sun Ultra 450 Workstation Owner s Guide or Ultra Enterprise 450 Server Owner s Guide for instructions on how to remove disk drives 32 September 1998 Revision A...
Страница 41: ...g procedure you must know the slot number of the faulty disk 0 through 19 and its logical device name for example c2t3d0 If you know the disk slot number it is possible to determine the logical device...
Страница 42: ...d in the system console and logged in the usr adm messages file WARNING pci 6 4000 scsi 4 1 sd 3 0 sd228 Error for Command read 10 Error level Retryable Requested Block 3991014 Error Block 3991269 Ven...
Страница 43: ...s 11 If the output does not provide a slot number the device is either a removable media device CD ROM or tape drive or an external device Mapping From UNIX Logical Name to Disk Slot Number This secti...
Страница 44: ...ow to translate from a known disk slot number 0 through 19 to a UNIX logical device name such as c2t3d0 The example in this procedure assumes a known disk slot number of 3 1 Determine the UNIX physica...
Страница 45: ...s3 devices pci 1f 4000 scsi 3 sd 3 lrwxrwxrwx 1 root root 45 Jan 30 09 07 c0t3d0s4 devices pci 1f 4000 scsi 3 sd 3 lrwxrwxrwx 1 root root 45 Jan 30 09 07 c0t3d0s5 devices pci 1f 4000 scsi 3 sd 3 lrwxr...