(5)
Múltiplo de FLA
Vielfache des FLA-Wertes
Multiple of FLA
Intensités pleine charge multiples
Class 10
Class 15
Class 20
Class 30
Trip Curve
Courbe de déclenchement
Auslösekurve
Curva del disparo
HOT START
DEMARRAGE A CHAUD
WARMSTART
ARRANQUE EN CALIENTE
PARTIDA À QUENTE
AVVIAMENTO A CALDO
COLD START
DEMARRAGE A FROID
KALTSTART
ARRANQUE EN FRIO
PARTIDA À FRIO
AVVIAMENTO A FREDDO
Curva de disparo
Curva di intervento
0.1
1
10
100
1000
1
8
0.1
1
10
100
1000
1
8
0.1
1
10
100
1000
1
8
0.1
1
10
100
1000
1
8
Intensités pleine charge multiples
Multiplo di Max amp.
Short Circuit Ratings
Table 1 Standard Fault Short Circuit Ratings per UL508 and CSA 22.2 No. 14
Max. available fault
current (kA)
Max. voltage (V)
S.C.P.D.
ED1CP, ED1DP, ED1EP,
EECP, EEDP, EEEP, EEPP,
EERP, EESP
5
E1 Plus Cat. No.
Not resticted to
fusing only
193,193S
600
Table 4 High Fault Short Circuit Ratings per UL508 and CSA 22.2 No. 14
Contactor Cat. No.
Max. starter FLC
(A)
Max.available
fault current (kA) Max. voltage (V)
Max. UL Class J or CC
fuse, CSA HRCI-J (A)
20
20
30
40
100-C09
9
100-C12
12
100-C16
16
100-C23
23
E1 Plus Cat. No.
100
600
ED1CP, ED1DP, ED1EP,
EECP, EEDP, EEEP
193
Table 3 Short Circuit Ratings per EN 60947-4-1
Type 2 Fuse Selection Table for Class gG and Class aM Fuses
at Line Voltage of 400V, 50Hz
Prospective S.C.
current, Ir (kA)
Conditional S.C.
current, Iq (kA)
Max. voltage (V)
S.C.P.D.
ED1CP, ED1DP, EECP,
EEDP, EEPP, EERP
1
ED1EP, EEEP, EESP
3
E1 Plus Cat. No.
100
690
Not resticted to
fusing only
193, 193S
Table 2 Type I and Type II Fuse Coordination with Bul. 100-C contactors per EN 60947-4-1
Contactor Cat. No. Max. starter FLC
(A)
Prospective S.C.
current, Ir (kA)
Conditional S.C.
current, Iq (kA)
Max. voltage
(V)
Type I Max. Class
J or CC fuse (A)
Type II Max. Class
J or CC fuse (A)
193
E1 Plus Cat. No.
3
100
600
ED1EP, EEEP
ED1CP, ED1DP, EECP,
EEDP
1
15
20
30
40
15
20
30
40
20
20
30
40
20
20
30
40
9
12
16
23
9
12
16
23
100-C09
100-C12
100-C16
100-C23
100-C09
100-C12
100-C16
100-C23
42053-028-01
DIR 42053-028
(Version 03)
Contactor
Rated
Opera onal
Current I
e
Type gG
Rated
Current
Type aM
Rated
Current
Catalog
Number
Catalog
Number
Current
Setting
Range
Iq
[kW]
[A]
1)
[A]
[A]
2)
3)
[A]
[kA]
0.37
1.1
4
2
100-C09… 193-EECP
1.0 - 5.0
0.55
1.5
4
2
100-C09… 193-EECP
1.0 - 5.0
0.75
1.9
6
4
100-C09… 193-EECP
1.0 - 5.0
1.1
2.7
6
4
100-C09… 193-EECP
1.0 - 5.0
1.5
3.6
6
4
100-C09… 193-EECP
1.0 - 5.0
2.2
4.9
10
6
100-C09… 193-EEDP
3.2 - 16
3
6.5
16
10
100-C09… 193-EEDP
3.2 - 16
4
8.5
20
10
100-C09… 193-EEDP
3.2 - 16
5.5
11.5
25
16
100-C12… 193-EEDP
3.2 - 16
7.5
15.5
32
16
100-C16… 193-EEDP
3.2 - 16
Recommended fuse sizes based on the following starting conditions:
≤
3 kW Starting current max. 6 x Motor rated current, Starting time max. 5 s
> 3 kW Starting current max. 7 x Motor rated current, Starting time max. 5 s
1)
Typical motor currents according IEC 60947-4-1 Table G.1
2)
Incomplete catalog number, add coil and auxiliary contact codes
3)
Overload relay 193-ED… with the same current setting range may also be used (up to 45A)
Motor
Fuse
O/L Relay 193-EE..
S.C. Current
50