Allen-Bradley 1606-XLB240E Скачать руководство пользователя страница 2

Important User Information

Read this document and the documents listed in the additional resources section about installation, configuration, and 
operation of this equipment before you install, configure, operate, or maintain this product. Users are required to 
familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, 
and standards.

Activities including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are 
required to be carried out by suitably trained personnel in accordance with applicable code of practice.

If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may 
be impaired.

In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from 
the use or application of this equipment.

The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and 
requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or 
liability for actual use based on the examples and diagrams.

No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or 
software described in this manual.

Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, 
Inc., is prohibited

Throughout this manual, when necessary, we use notes to make you aware of safety considerations.

Labels may also be on or inside the equipment to provide specific precautions.  

WARNING: 

Identifies information about practices or circumstances that can cause an explosion in a hazardous 

environment, which may lead to personal injury or death, property damage, or economic loss.

ATTENTION: 

Identifies information about practices or circumstances that can lead to personal injury or death, property 

damage, or economic loss. Attentions help you identify a hazard, avoid a hazard, and recognize the consequence.

IMPORTANT

Identifies information that is critical for successful application and understanding of the product.

SHOCK HAZARD: 

Labels may be on or inside the equipment, for example, a drive or motor, to alert people that dangerous 

voltage may be present.

BURN HAZARD: 

Labels may be on or inside the equipment, for example, a drive or motor, to alert people that surfaces may 

reach dangerous temperatures.

ARC FLASH HAZARD: 

 Labels may be on or inside the equipment, for example, a motor control center, to alert people to 

potential Arc Flash. Arc Flash will cause severe injury or death. Wear proper Personal Protective Equipment (PPE). Follow ALL 
Regulatory requirements for safe work practices and for Personal Protective Equipment (PPE).

Содержание 1606-XLB240E

Страница 1: ...Basic Power Supply 10 A Catalog Number 1606 XLB240E Reference Manual OriginalInstructions...

Страница 2: ...nformation circuits equipment or software described in this manual Reproduction of the contents of this manual in whole or in part without written permission of Rockwell Automation Inc is prohibited T...

Страница 3: ...Mean Time Between Failure MTBF 13 Protection Features 6 Functional Diagram 13 Safety Features 7 EMC 14 Installation Notes 7 Application Notes 15 Terminals and Wiring 7 Specifications 15 Installation N...

Страница 4: ...Hz mains frequency AC 120V parameters are valid for 60 Hz mains frequency AC 230V A figure that is displayed with the AC or DC before the value represents a nominal voltagewith standardtolerances inc...

Страница 5: ...158 F This power supply features a wide input voltage range which makes it suitable for global use The addition of a DC OK signal makes the power supply ideal for many industry applications such as pr...

Страница 6: ...E Output protection Electronically protected against overload no load and short circuits 1 1 If there is a protection event audible noise can occur Output overvoltage protection typ 30 5V DC max 32 V...

Страница 7: ...einforced insulation IEC EN 60204 1 EN 50178 IEC 62103 IEC 60364 4 41 Class of protection I PE Protective Earth connection required Isolation resistance 5 MOhm input to output 500V DC Touch current le...

Страница 8: ...t 24V 10 A Start up delay typ 400 ms 260 ms 200 ms see Figure 4 Rise time typ 60 ms at 24V 10 A const current load 0 mF load capacitance seeFigure 4 typ 230 ms at 24V 10 A const current load 5 mF load...

Страница 9: ...on max 14 5 A peak 17 A peak 32 A peak 40 C 104 F ambient cold start typ 7 A peak 8 5 A peak 16 A peak 40 C 104 F ambient cold start Inrush energy typ 11 5 A peak 14 A peak 26 A peak 25 C 77 F ambien...

Страница 10: ...continuous current output voltage 13V DC see Figure 7 HiccupPLUS mode output voltage 13V DC see Figure 7 Short circuit current min 11 A 2 load impedance 50mOhm see Figure 7 max 15 A load impedance 50m...

Страница 11: ...s 53 ms 53 ms 24V 10 A typ 32 ms 32 ms 32 ms min 26 ms 26 ms 26 ms Figure 9 Hold up Time vs Input Voltage Figure 10 Shut down Behavior Definitions 0 10 20 30 40 80ms 90 120 230Vac Input Voltage 50 60...

Страница 12: ...ad for 25 of the time 50 of the nominal load for another 25 of the time 75 of the nominal load for another 25 of the time and with 100 of the nominal load for the rest of the time Figure 12 Efficiency...

Страница 13: ...Lifetime expectancy is specified in operational hours and is calculated accordingtothecapacitor smanufacturerspecification Themanufactureroftheelectrolyticcapacitorsonlyguaranteesamaximum life of up...

Страница 14: ...ge sags SEMI F47 0706 dips on the input voltage according to SEMI F47 standard 80 of 120V AC 96V AC 70 of 120V AC 84V AC 50 of 120V AC 60V AC 50 of 120V AC 60V AC 1000ms 500ms 200ms 200ms Criterion A...

Страница 15: ...in one branch circuit the fuse or circuit breaker need a certain amount of overcurrent to open in a timely manner This avoids voltage loss in adjacent circuits The extra current peak current is suppl...

Страница 16: ...If an external fuse is necessary or utilized minimum requirements need to be considered to avoid nuisance tripping of the circuit breaker A minimum value of 10A B characteristic or 6A C characteristic...

Страница 17: ...ect as many units in series as needed providing the sum of the output voltage does not exceed 150V DC Voltages with a potential above 60V DC are not SELV any more and can be dangerous Such voltages mu...

Страница 18: ...three phase system Such a phase to phase connection is allowed as long as the supplying voltage is below 240V 10 Figure 20 Operation on Two Phases Use in a Tightly Sealed Enclosure When the power sup...

Страница 19: ...24 28V DC Output Current 10 A at 24V amb 55 C 131 F 6 25 A at 24V amb 70 C 158 F 8 6 A at 28V amb 55 C 131 F 5 4 A at 28V amb 70 C 158 F Output power 240 W ambient 55 C 131 F 150 W ambient 70 C 158 F...

Страница 20: ...1000 m 2000 m 6500 ft seeFigure 22 Overvoltage category III IEC 62103 EN 50178 altitudes up to 2000 m II altitudes from 2000 m to 6000 m Degree of pollution 2 IEC 62103 EN 50178 not conductive LABS co...

Страница 21: ...testing set the cutoff current settings to the value in the following table Figure 23 Dielectric Strength To meet the PELV requirements according to EN60204 1 6 4 1 we recommend that either the pole t...

Страница 22: ...EN 60950 1 EN 61000 6 UL 508 Listed for use as Industrial Control Equipment U S A UL 508 and Canada C22 2 No 14 15 File E56639 UL 60950 1 Recognized for use as Information Technology Equipment U S A U...

Страница 23: ...aterial of Housing FlameretardantPolycarbonate PC UL94 V0Vicatsofteningtemperaturespecifiedwith149 C 300 F according to ASTM D1525 Installation Clearances Keep the following installation clearances 40...

Страница 24: ...24 Rockwell AutomationPublication 1606 RM056A EN P December 2016 Basic Power Supply 10 A Notes...

Страница 25: ......

Страница 26: ...al Code for your product Use the code to route your call directly to a technical support engineer http www rockwellautomation com global support direct dial page Literature Library Installation Instru...

Отзывы: