background image

PL-8

 User Guide   AP5270 issue 3 

Wiring the logic outputs   

The 7way output terminal block 

provides four logic output connections.    Pins  5  to  7  ‘G’  are  used  as  the 
common return ground.  One wire can feed this ground to a bank of indicators 
or other devices. 

The output works by switching the in5V reference supply through a 470 
ohm resistor to the pin.  This presents a positive voltage when the output is 
turned on, and an open circuit when it is turned off.  The switching is done 
using a transistor.  The resistor limits the current to a maximum 10mA to ensure 
the connected equipment does not draw more than the 

PL-8

 can provide. 

The  output  may  be  used  in  many  ways  to  satisfy  a  range  of  interfacing 
applications.  It is important that the installer has a good working knowledge of 
interfacing circuits.  Incorrect application may result in damage to the 
equipment.  Typical applications include powering an LED indicator and 
switching solid state (low current) relays. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This product complies with the European Electromagnetic 
Compatibility directives 89/336/EEC & 92/31/EEC. 

NOTE:

   Any changes or modifications to the equipment not approved by Allen 

& Heath could void the compliance of the equipment.  Whilst we believe the 
information in this guide to be reliable we do not assume responsibility for 
inaccuracies. We also reserve the right to make changes in the interest of 
further product development. 

Copyright© 2005 Allen & Heath Ltd. All rights reserved. 

1K5

CONTROL

CHAIN

OPTO-ISOLATED SWITCH INPUTS

LOGIC OUTPUTS

PL-8

INPUTS

PL-Anet OUT

PL-Anet IN

OUTPUTS

LED INDICATOR

RELAYS

+

-

LAMPS

MOTORS

EQUIPMENT

DEVICE

+20V

+5V

G

G

To next PL-Anet device

or terminator

From iDR or previous

PL-Anet device

SWITCH

SWITCH

SWITCH

SWITCH

SOLID STATE

1 2 3 4 G

G

2 3 4

1

470R SERIES RESISTOR

G

G

LED INDICATOR

G

470R

+5V

INTERNAL PL-8 CIRCUIT

(1 OF 4 SHOWN)

SERIES RESISTOR

TYPICALLY 6mA

2 3 4 G

G

1

Specification 

 

In/Out Connectors: 

Phoenix 7way screw terminal blocks 
For permanent bare wire connection 
 

Switch Inputs: 

4x opto-isolated switch closure inputs 
+5V DC through series 1k5 ohm resistor 
Switch closure connects pin to ground 
Maximum current when switched = 1.2mA 
Maximum cable resistance = 1k ohm 
Switch types:   

Momentary action 

 

      

Microswitch 

 

 

Relay contact 

  Custom 

interface 

 

Logic Outputs: 

4x transistor logic outputs 
Uses internal PL-Anet supply 
ON = +5V DC through series 470 ohm resistor 
OFF = open circuit 
Output voltage depends on current drawn 
Maximum current per output (shorted) = 10mA 
Output capability: 

LED indicator 

 

 

Solid state relay 

  Custom 

interface 

 

Communication: 

RS485 based PL-Anet serial port 
RJ45 input and output connectors 
Maximium 15x addresses per PL-Anet branch 
 

Configuration: 

iDR System Manager software V3.1 or greater 
Refer to the software Help file 
Separately configure switches and outputs 
Input switch function: Volume up/down 
 

 

Mute on/off 

  Patch 

recall 

 

 

Monitor select 

Logic output function:  Static on/off 
 

 

Mute status 

 

 

Soft switched 

  Patch 

recalls 

 

 

Scheduled events 

 

Power Supply: 

In5V DC from PL-Anet 20V supply 
Minimum PL-Anet voltage at 

PL-8

 = 11V 

Maximum logic output = 40mA (all shorted) 

Содержание PL Series

Страница 1: ...lable visit our web site http www allen heath com The Application The diagram above shows an example of a remote control network using an iDR 8 The iDR 4 could also be used Various PL devices are installed in different parts of the building for example PL 3 and PL 4 wall plates for room volume control and source select PL 6 fader panel for remote mixing in a conference room and PL 8 units for dist...

Страница 2: ...from the Allen Heath web site Description the PL 8 comes supplied with two PCB assemblies attached to a brushed aluminium wall plate This enables it to be mounted into a standard single gang wall backing box A UK EU European or US American size plate together with fixing screws is provided according to which version has been ordered The top PCB houses the circuit which interfaces to the iDR PL Ane...

Страница 3: ... Its green active LED should be lit If not use the iDR System Manager software Communications Option menu to activate the port Plug in the PL Anet cable The iDR System Manager screen should display icons for each PL device it recognises If you do not have the iDR available you can configure the software off line Refer to the Help file for details on programming the PL functions Diagnostics If a fa...

Страница 4: ...ed 1K5 CONTROL CHAIN OPTO ISOLATED SWITCH INPUTS LOGIC OUTPUTS PL 8 INPUTS PL Anet OUT PL Anet IN OUTPUTS LED INDICATOR RELAYS LAMPS MOTORS EQUIPMENT DEVICE 20V 5V G G To next PL Anet device or terminator From iDR or previous PL Anet device SWITCH SWITCH SWITCH SWITCH SOLID STATE 1 2 3 4 G G 2 3 4 1 470R SERIES RESISTOR G G LED INDICATOR G 470R 5V INTERNAL PL 8 CIRCUIT 1 OF 4 SHOWN SERIES RESISTOR...

Отзывы: