PL-8

 User Guide   AP5270 issue 3 

Installing the PL-8   

Mount the assembly into a single gang backing 

box located in a wall or suitable furniture.  If necessary, it may be installed in a 
hidden location such as a ceiling void or cupboard as it is not necessary for the 
operator to have access to the module.  Minimum recommended internal box 
depth is 32mm.  We recommend that you provide enough space in the cavity 
behind the box to allow a service loop for the wiring to the module. 

  

Grounding metal plates

   Ensure that the metal face plate 

is correctly grounded to ensure safety.  The plate should be connected to a 
local safety ground.  Use a ground wire or physical contact with a grounded 
back  box.    The  same  applies  to  any  exposed metal surfaces used within the 
system.  

 

PL-Anet wiring

   Use flame retardent CAT5 STP (shielded twisted pair) 

cable terminated with RJ45 connectors.  Do not use UTP cable.  We 
recommend the multi-stranded rather than solid conductor type.  The 
connection follows the EIA/TIA 568B wiring colour scheme.  Ensure all ports 
and cables in the system are wired to this scheme. 

 

Connecting to an iDR unit   

The 

iDR 

unit communicates with 

the 

PL-8

 using the PL-Anet port.  This serial connection can be daisy chained 

through several 

PL

 wallplates as shown.  Make sure you plug the PL-Anet IN 

and OUT sockets correctly.   

End of chain termination

   As with any RS485 system, the last 

PL

 

device needs to have a terminating resistor fitted to its output port.  Each 

PL-8

 

is shipped with a terminator plug already fitted in its PL-Anet output socket.  
Leave this fitted only if the unit is the last in the chain. 

Programming the controls

   iDR System Manager software 

version V3.1 or later is required.  Check the Allen & Heath web site for the latest 
software.  Ensure that the 

iDR

 PL-Anet port is active.  Its green ‘active’ LED 

should  be  lit.    If  not,  use  the  iDR  System Manager software Communications 
Option menu to activate the port.  Plug in the PL-Anet cable.  The iDR System 
Manager screen should display icons for each PL device it recognises.  If you 
do not have the 

iDR

 available you can configure the software off line.  Refer to 

the Help file for details on programming the PL functions. 

Diagnostics

   If a fault is suspected check the two diagnostics LEDs on 

the underside of the 

PL-8 

connector PCB.  Both the red and green LEDs 

should be lit once communication with the 

iDR

 is established.  If a fault is 

found, first check for correct wiring.  If further assistance is required contact 
Allen & Heath technical support. 

 

Wiring terminals   

Phoenix type screw terminal connectors are used 

for connecting the external switches and logic to the 

PL-8.  

Make sure the wire 

ends are carefully stripped and inserted into the terminals.  Tighten the screws 
using a small slotted screwdriver.  To ensure interference-free operation we 
recommend you use shielded cable. 

Wiring the switch closure inputs  

 The 7way input terminal 

block provides 4 switch input connections.  Pins 5 to 7 ‘G’ are used as the 
common switch ground.  One wire can feed this ground to a bank of switches.  
Two switches are shown wired in the diagram here. 

The switch works by linking its connector pin to any ground (‘G’) pin.  Use a 
contact closure such as a momentary press switch, microswitch or relay to do 
this.  Low current switches may be used.  We recommend good quality sealed 
components for reliable operation. 

The input pin is fed from the in5V reference supply through a 1k5 ohm 
resistor.  It uses an opto-coupler to isolate the 

PL-8

 from the connected 

equipment.  Approximately 1.2mA minimum current flows when connected to 
ground.  Combined switch and cable resistance should not exceed 1k ohm for 
the switch to activate. 

INTERNAL PL-8 CIRCUIT

(1 OF 4 SHOWN)

2 3 4

G

1

G G

INPUTS

SWITCH

SWITCH

+5V

1K5

OPTO

OUT

IN

OUT

IN

PL-Anet

TE

RM

IN

AT

OR

 PL

UG

Содержание PL Series

Страница 1: ...lable visit our web site http www allen heath com The Application The diagram above shows an example of a remote control network using an iDR 8 The iDR 4 could also be used Various PL devices are installed in different parts of the building for example PL 3 and PL 4 wall plates for room volume control and source select PL 6 fader panel for remote mixing in a conference room and PL 8 units for dist...

Страница 2: ...from the Allen Heath web site Description the PL 8 comes supplied with two PCB assemblies attached to a brushed aluminium wall plate This enables it to be mounted into a standard single gang wall backing box A UK EU European or US American size plate together with fixing screws is provided according to which version has been ordered The top PCB houses the circuit which interfaces to the iDR PL Ane...

Страница 3: ... Its green active LED should be lit If not use the iDR System Manager software Communications Option menu to activate the port Plug in the PL Anet cable The iDR System Manager screen should display icons for each PL device it recognises If you do not have the iDR available you can configure the software off line Refer to the Help file for details on programming the PL functions Diagnostics If a fa...

Страница 4: ...ed 1K5 CONTROL CHAIN OPTO ISOLATED SWITCH INPUTS LOGIC OUTPUTS PL 8 INPUTS PL Anet OUT PL Anet IN OUTPUTS LED INDICATOR RELAYS LAMPS MOTORS EQUIPMENT DEVICE 20V 5V G G To next PL Anet device or terminator From iDR or previous PL Anet device SWITCH SWITCH SWITCH SWITCH SOLID STATE 1 2 3 4 G G 2 3 4 1 470R SERIES RESISTOR G G LED INDICATOR G 470R 5V INTERNAL PL 8 CIRCUIT 1 OF 4 SHOWN SERIES RESISTOR...

Отзывы: