background image

 

               

User Guide 

 AP11137 iss.1  

 

  9

        

 

 

                           

ALLEN

&

HEATH

 

4.

 

Rear Panel 

 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

USB port

 

 For data transfer 

between ME-500 mixers or 

to back up the settings to 

computer. 
The preset is stored as a file 

named PRESET.ME5 in the 

ME500PST folder on the 

USB device. 
Also used for updating the 

ME-500 operating firmware. 

Phones

 

 3.5mm mini-jack 

and ¼” TRS stereo jack to 

connect one or two 

headphones or earpieces, 

or stereo line level 

equipment such as a 

wireless in-ear transmitter.  
Tip=Left, Ring=Right. 

Mono Out

 

 Balanced TRS 

jack to connect to mono line 

level equipment such as a 

powered speaker or drum 

throne. 
The output is the mono sum of 

the Left and Right mix.  
Tip=Hot, Ring=Cold 

DC In

 

 External PSU (power 

supply) input. Plug in the DC 

cable of the mains power unit 

provided with the ME mixer. 

Note

   

Only use power supply: 

ENG Electric 6A-161WP12 

(A&H part code AM10314) 
Alternatively, the mixer can be 

powered via the Link In Cat5 

cable when connected to a 

PoE (Power over Ethernet) 
switch or the ME-U hub. 

Link Out

 

 Locking EtherCON 

connector to plug a Cat5 

cable to feed audio to the next 

ME mixer when daisy 

chaining them together. 
Link Out does not carry PoE 

power. Daisy chained mixers 

are powered using their 

external power units. 
 

Link In

 Locking EtherCON 

connector to plug a Cat5 

cable from the source. 
Receives up to 32 channels 

of audio and stereo link 

information when connected 

to a ME compatible Allen & 

Heath console, or 16 

channels when connected 

to Aviom

®

 A-Net 16. 

The mixer can receive 

power over this Cat5 link if 

connected to a 

PoE

 switch 

or the ME-U hub. 

Monitor Link

 

 Proprietary Allen & Heath Ethernet based Cat5 connection that 

carries 40 channels of 48kHz digital audio and stereo link data from the source 

console to ME personal monitor mixers. 

ME-1

 uses CH1-40. Channels can be assigned to its keys in any order and be 

configured for single, stereo or grouped operation at the ME-1. 

ME-500

 uses CH1-32 depending on how many channels are linked for stereo 

operation at the source console. Channels are automatically assigned to the 16 

keys starting with CH1. Stereo linked pairs are assigned to a single key. 
 
 

Содержание ME 500

Страница 1: ...User Guide AP11137 iss 1 1 ALLEN HEATH Personal Mixer User Guide Publication AP11137...

Страница 2: ...shall be liable for any incidental or consequential damages or breach of any express or implied warranty of this product Conditions Of Warranty The equipment has not been subject to misuse either int...

Страница 3: ...e before use Avoid using the mixer in direct sunlight Recommended operating temperature is 5 to 35 degrees Celsius Clean the control surface with a soft brush and dry lint free cloth Do not use chemic...

Страница 4: ...13 6 6 Adjusting Master level 13 6 7 Working with Channels 13 6 8 Working with the Master 13 6 9 Setting the output limiter 13 6 10 Trimming all levels 13 6 11 ME 500 Presets 14 6 12 USB Preset transf...

Страница 5: ...o meet your application requirements More information provided later in this guide Accessories Microphone stand side mounting bracket The mixer has a built in 3 8 thread to mount it to the top of a mi...

Страница 6: ...limiter and 3 band EQ 16 User presets Group function Name display 3 5mm Jack Aux input Built in ambient mic Built in signal generator Includes stand bracket Includes headphone hook ME 500 and ME 1 mix...

Страница 7: ...er Ethernet switch or the 10 port Allen Heath ME U PoE hub Designed for the application Compact and smart on stage Easy to read display screen Backlit keys for viewing in the dark Surface plinth or mi...

Страница 8: ...ettings Key10 From USB key Preset Store mode Hold Shift Recall and press a select key to store current level pan and mute settings Key1 8 To user presets Key10 To USB key Solo key Press to enter solo...

Страница 9: ...t switch or the ME U hub Link Out Locking EtherCON connector to plug a Cat5 cable to feed audio to the next ME mixer when daisy chaining them together Link Out does not carry PoE power Daisy chained m...

Страница 10: ...ltiple ME mixers Use a Layer 2 unmanaged switch that supports 100 Mbit s Fast Ethernet Note Layer 3 or 4 protocols can cause audio clicks or interruption Note Aviom A Net 16 is not compatible with sta...

Страница 11: ...reo signal is duplicated on the large and small output sockets Use a stereo Y cable to feed equipment with separate left and right inputs The output is unbalanced To connect to balanced equipment link...

Страница 12: ...rs Refer to the console user guide for instructions You can patch any combination of input channels group and mix outputs to the 40 ME monitor channels ME 500 uses up to 32 channels depending on how m...

Страница 13: ...flashes when solo is active Press and hold for more than 1 second for momentary action 6 8 Working with the Master Press the Master key to work with the output Mute Press the Mute key to toggle the mi...

Страница 14: ...ilable to recall While holding down Recall press a Select key to recall its preset The current mixer settings are overwritten with the contents of the preset Use Keys1 8 to recall mixer presets Use Ke...

Страница 15: ...st version of firmware This can be downloaded and transferred to the ME mixer via USB key To start the update press and release the rotary while holding down Shift Key16 For more information refer to...

Страница 16: ...User Guide AP11137 iss 1 16 ALLEN HEATH...