background image

iDR-8

 User Guide 

Rear Panel Overview 

 1

   Mains input

   Use the IEC lead with moulded 

mains plug suitable for your local mains voltage.  
The protection fuse rating  is  marked  on  the  rear 
panel.  The on/off switch is positioned on the rear 
panel to prevent accidental operation. 

 2

    Network port

  RJ45 socket for connection to 

an Ethernet network or PC using UTP CAT5 cable.  
This port is recommended for configuring the 
system with iDR software.  The MDI/X switch 
selects network or direct to PC operation.  The link 
LED lights when communication is established.  
The TX LED lights when data is communicated. 

Note:

  The RS232, MIDI, SysNet and PL-Anet 

control ports are not all available at the same time.  
A combination of two is selected using iDR 
System Manager.  The associated active LED 
lights when the port is available. 

 3

   RS232 (MODEM) port

      This  is  used  for 

connection to a modem so that the unit can be 
interrogated by a remote PC over a standard 
telephone line.  It can also be used for system 
configuration using iDR System Manager software 
but the faster network port is recommended.  
Pressing the front panel switch selects either the 
front or rear RS232 port. 

 4

    MIDI port

   Standard opto-isolated MIDI port 

with IN, THRU and OUT connectors. 

 5

      SysNet  port

      An  RS232  serial  port  for 

communication with third party remote controllers 
running the Allen & Heath SysNet protocol. 

 6

   PL-Anet port

   An RS485 serial port for 

communication with a network of Allen & Heath 
PL wall plates and remote controllers using CAT5 
STP cable. 

 7

   DR-Link port

   RJ45 socket for control of iDR 

audio and logic expander units using CAT5 STP 
cable.  IN and OUT ports are provided on the 
expander units so that the control can be daisy 
chained through a system with more than one 
expander. 

 8

   Audio expander ports

   RJ45 sockets for 

communicating 8 channel digital audio between 
the 

iDR-8

 and its expanders using CAT5 STP 

cable.  Two cables are required between the 
expander and 

iDR-8

, one for the audio, the other 

for DR-Link control. 

 9

   Mic/Line inputs

      Balanced  XLR  inputs  for 

microphone and line level sources.  Adding the 

iDR-in

 expands the 

iDR-8

 to 16 inputs. 

 10

   Audio outputs

  Balanced XLR line level 

outputs with m18dBu level.  Adding the 

iDR-out

 expands the 

iDR-8

 to 16 outputs. 

 11

   Monitor inputs and outputs

  Balanced TRS 

jacks for L and R monitor inputs and outputs.  
These provide a line level version of the front 
panel stereo headphones output and can daisy 
chain through multiple iDR units. 

 12

   Switch closure inputs

  These are provided 

on the 

iDR-switch

.  They can be hard wired from 

remote wall plate and controller switches and 
relays. 

 13

   Open collector logic outputs

  These are 

provided on the 

iDR-switch

.  They can be used to 

control LEDs, lamps, relays and other devices. 

 14

   Earth terminals

  These are provided to earth 

(ground) the switch and logic output cable 
shields. 

Use null-modem cable to connect to PC com port

CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN.

FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING.

ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES.

THIS APPARATUS MUST BE EARTHED.

WARNING

47-63Hz ~ 90W MAX

100 - 240V~

active

RS232 (MODEM)

Complies with UL6500, CSA-E65, EN60065

MONITOR OUT

LINK

TX

Refer to user guide for port selection details

FUSE: T1.6AL

AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.

SERIAL NUMBER

Made in the UK by ALLEN&HEATH LIMITED

MONITOR IN

DIGITAL EXPANDER

R

PL-ANET

DR-LINK

L

R

AUDIO OUT

AUDIO IN

THRU

active

MDI/X

NETWORK

MIDI OUT

active

MIDI IN

active

SYSNET PORT

L

OUT 8

OUT 7

OUT 5

LINE OUTPUTS

OUT 6

OUT 4

IN 8

IN 7

IN 5

MIC/LINE INPUTS

IN 6

IN 4

OUT  3

OUT  2

OUT  1

IN 3

IN 2

IN 1

Made in the UK by ALLEN&HEATH LIMITED

AUDIO OUT

CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN.

FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING.

ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES.

47-63Hz ~ 25W MAX

100 - 240V~

THIS APPARATUS MUST BE EARTHED.

WARNING

SERIAL NUMBER

AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.

FUSE: T500mAL

next

OUT DR-LINK

previous

IN

IN 10

Complies with UL6500, CSA-E65, EN60065

IN 16

IN 15

MIC/LINE INPUTS

IN 14

IN 13

IN 11

IN 12

IN 9

AUDIO IN

Made in the UK by ALLEN&HEATH LIMITED

CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN.

FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING.

ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES.

THIS APPARATUS MUST BE EARTHED.

WARNING

47-63Hz ~ 25W MAX

100 - 240V~

SERIAL NUMBER

FUSE: T500mAL

AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.

next

OUT DR-LINK

previous

IN

OUT 10

Complies with UL6500, CSA-E65, EN60065

OUT 16

OUT 15

LINE OUTPUTS

OUT 14

OUT 13

OUT 11

OUT 12

OUT 9

V

G

G

4

3

2

1

G

5

6

7

8

G

12 11 10 9

G

13

14

15

16

G

20 19 18 17

G

21

22

23

24

SWITCH INPUTS

LOGIC OUTPUTS

1

2

3

+

-

4

V

G

V

G

V

G

+

- +

- +

-

5

6

7

+

-

8

+

- +

- +

-

9

10

+

- +

- +

- +

-

11

12

14

+

- +

- +

- +

-

15

16

13

switch

G

opto

+10V

2K2

opto

+

-

V

G

+10V DC max total 500mA

open collector

+24V DC, 200mA max

+10V

FUSE: T500mAL

WARNING

THIS APPARATUS MUST BE EARTHED.

ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES.

FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING.

100 - 240V~

47-63Hz ~ 15W MAX

CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN. AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.

Made in the UK by ALLEN&HEATH LIMITED

Complies with UL6500, CSA-E65, EN60065

OUT

IN

DR-LINK

next

previous

TO AVOID DAMAGE ONLY CONNECT

CAUTION 20V DC

COMPATIBLE REMOTE CONTROL

EQUIPMENT TO THE PL-ANET PORT.

DIGITAL EXPANDER

DIGITAL EXPANDER

Содержание iDR-8

Страница 1: ...USER GUIDE Hardware Configuration For software configuration refer to the iDR System Manager Help file Publication AP4530 iDR 8 Digital Audio Mix Processor ...

Страница 2: ...nterest of further product development Allen Heath Limited Kernick Industrial Estate Penryn Cornwall TR10 9LU UK http www allen heath com Limited One Year Warranty This product is warranted to be free from defects in materials or workmanship for period of one year from the date of purchase by the original owner To ensure a high level of performance and reliability for which this equipment has been...

Страница 3: ...nit away from any equipment which produces heat such as power supplies power amplifiers and heaters Environment Protect from excessive dirt dust heat and vibration when operating and storing Avoid tobacco ash drinks spillage and smoke especially that associated with smoke machines Handling To prevent damage to the controls and cosmetics avoid placing heavy objects on the equipment surfaces scratch...

Страница 4: ...d additional support information can be downloaded For information on the status and availability of the features described in this user guide and any changes and new additions please refer to the Release Notes which come with the current version of operating software We are able to offer further product support through our world wide network of approved dealers and service agents Our web site pro...

Страница 5: ...ings 19 Rebooting the iDR 8 19 Getting Started Checking the Hardware 20 Communicating with the iDR 8 21 Communicating Using TCP IP 22 Connecting Direct to a PC 23 Connecting to a Network 23 Communicating Using a Dial Up Connection 24 Connecting to a Modem Using RS232 25 Connecting to a PC Using RS232 25 Working with iDR System Manager 26 Setting the Time and Day Clock 26 Archiving and Loading Conf...

Страница 6: ...re and 48 open collector logic outputs In addition you can choose two of the following MIDI the Sys Net serial port to interface with third party remote controllers RS232 for modem communication and the PL Anet serial port for running a network of Allen Heath PL wall plates and controllers The iDR 8 features networked control It is configured using the iDR System Manager software via an Ethernet p...

Страница 7: ...ontrollers MIDI port IN OUT and THRU sockets provided for remote control using show controllers and other MIDI equipment 16 Front panel soft keys can be assigned by the installer as level mute or patch recall with different types of press action Similar applies to the iDR switch functions 32 Front panel 3 colour soft LEDs can be assigned by the installer as signal meters mute or patch related indi...

Страница 8: ...lects either the front or rear RS232 port The active LED lights when the port is available 10 Code update switch Puts the unit into code update mode ready to accept new operating code from a PC Status is shown on the LCD 11 Status LEDs Both the slave and ext sync lock LEDs light when the unit is correctly working as a slave in a daisy chained iDR system The 96k LED is available for a possible futu...

Страница 9: ... are provided on the iDR switch They can be used to control LEDs lamps relays and other devices 14 Earth terminals These are provided to earth ground the switch and logic output cable shields Use null modem cable to connect to PC com port CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING ATTENTION REMPLACER LE FUSIBLE AV...

Страница 10: ...each may be added This means that you can create an 8x8 16x8 8x16 or 16x16 system to suit your requirements The stereo monitor input and output can also be added into the matrix in a non expanded iDR 8 to create a 10x10 system iDR 8 and iDR 4 units can be daisy chained together using the 8 channel wide digital expander bus to create even more flexible systems with additional local inputs and outpu...

Страница 11: ...the active monitor bus and can also be routed into the source patchbay The outputs are fed from a patchbay which gets its source from the active monitor bus or any output channel In this way these connections can be used either as a monitor system or as channels in their own right Signal generator Provides another selectable source feeding the input channels through the patchbay Variable frequency...

Страница 12: ...ch and polarity reverse The fader offers 5dB boost above the unity gain 0 position The matrix provides variable level crosspoints with independent fader control Groups and stereo linking Faders can be grouped so that a master fader takes control of assigned input or output faders Channels can be linked for stereo operation with single fader level control and linked processing throughout the audio ...

Страница 13: ...E NOTES This file contains important notes about the related version of the software Read before starting iDR SYSTEM MANAGER APPLICATION to configure and control the iDR system using a PC running Windows WINDOWS HELP FILE for the iDR System Manager application iDR UNIT OPERATING CODE This is pre installed in the iDR 8 unit However check that it is the latest version Update the code as described la...

Страница 14: ...re adequate air flow around the units Do not install the units directly above or below heat or electromagnetic generating equipment such as power supplies and amplifiers To avoid damage to the internal assemblies do not fit screws or drill through the case metalwork Do not remove the cover of the iDR unit There are no user serviceable parts inside All configuration is carried out using the front p...

Страница 15: ...connectors and check for accurate wiring and reliable solder joints Avoid running audio cables alongside mains computer or lighting cables or near thyristor dimmer and power supply units If unavoidable cross the cables at right angles or run them in separate screened trunking to reduce the interference pickup Use low impedance sources such as 600Ω or less microphones to reduce susceptibility to in...

Страница 16: ...cks or thumps always turn connected power amplifiers down or off before switching the iDR 8 or any other signal equipment on or off Turn the unit on by pressing the rear panel power ON OFF switch The LCD display lights up and the message Please wait is displayed while the processor boots up This is followed by a Recall message if a power up patch is active Finally the normal display is shown Note ...

Страница 17: ...rminal window is opened 2 Select the file to transfer From the Transfer menu select the Send File item Click on the Browse button The file named iDR Unit Software V3_nn bin is displayed Make sure the version number is the same as the one you want to load Open the file The Send File window is opened ready to send the file via the COM port Do not do this until you have prepared the iDR 8 3 Prepare t...

Страница 18: ...oll character scroll character scroll character 4 Unit Name iDR iDR iDR Max 16 characters scroll day 3 Day of Week DAY Tuesday scroll hours scroll minutes scroll seconds 2 Clock TIME 12 44 41 TIME 12 44 41 TIME 12 44 41 scroll patches 1 Patch Select 01 Name DR 8 AUDIO MIX PROCESSOR REMOVE THESE SCREWS PRESS AND HOLD FOR 2 SECONDS The iDR 8 Setup Menus 1 Patch Select Scroll through the available pa...

Страница 19: ...elect menu 8 Diagnostics Scroll through the various sub menus to view the current settings Menu 8 1 8 2 and 8 3 display the last current IP address Subnet Mask and Gateway address if applicable Make a note of these if you need to restore them later Note that the address shown is likely to be temporary if the unit is working with a DHCP server Menu 8 4 displays the unique MAC address belonging to t...

Страница 20: ... out after 2 seconds of inactivity You should see the level displayed as a bar and number on the LCD display To get audio to pass through the unit you need to raise both the input fader and the required output fader In this default configuration all inputs are routed through the matrix to all outputs You can use one input to test each output by raising the output levels in turn Similarly you can u...

Страница 21: ...ore recommended for configuring the iDR system RS232 COM Port You can communicate with the iDR 8 via the COM1 or COM2 RS232 serial port on your PC NOTE By the nature of RS232 serial communication it is much slower than the network connection For this reason we recommend that you use it only when absolutely necessary or when dialing up the unit using a modem via a telephone line to remotely interro...

Страница 22: ...CAT5 Category 5 the standard used for network cabling and associated connectors UTP STP Unshielded Twisted Pair or Shielded Twisted Pair the type of cable used The cable has four twisted pairs of wires STP is shielded to reduce interference pickup TCP IP Transmission Control Protocol Internet Protocol a set of layered industry standard protocols which define network communication IP address the un...

Страница 23: ...lug it into the network until you have configured its settings Refer to the network administrator for the required DHCP setting and IP addresses 2 Set the iDR 8 IP settings Access the front panel menu system Go to menu 5 Network Setup Under menu 5 1 set DHCP to YES or NO as required If set to NO then go to menu 5 2 and set the IP Address Then go to menu 5 3 and set the Subnet Mask Exit and reboot ...

Страница 24: ...Option window You can select from the displayed combinations which options are associated with serial ports A and B To use RS232 make sure one of the top three is selected Reboot the iDR 8 for the changes to take effect Setting up a Dial up Connection You can simply use the factory default PPP settings In that case skip step 1 below However you can change these if you have a reason to do so Do thi...

Страница 25: ...l or the rear panel RS232 port Check that the active indicator is lit and that RS232 has been previously selected as the A port in the iDR System Manager File Preferences Communications Options item Use a standard RS232 cable for front connection Use a null modem female to female cable for rear connection 2 Dial up the iDR 8 Open up the previously created dial up connection Enter the correct usern...

Страница 26: ...e removed access menu 2 Clock and menu 3 Day of Week iDR System Manager software Click on the Edit menu Set Time item You can manually enter the settings or use the Sync to PC button to load in the current PC time and day settings Archiving and Loading Configurations The way the iDR 8 is set up and the contents of any patches which have been created is stored as a configuration It can be archived ...

Страница 27: ... are turned down or muted before you switch 48V on or off or plug microphones into powered inputs Do not connect unbalanced sources or cables to the inputs when 48V is selected If phantom power is not required make sure 48V is turned off Selecting PAD Select the 20dB pad if you are plugging in high level microphone or line sources Open on the Source window to access the 20dB switch Setting GAIN Op...

Страница 28: ...outputs into a stereo amplifier driving monitor loudspeakers You can select the source to monitor in three ways 1 Front panel Setup menu 7 With the face plate removed press and hold the MENU key until the Setup menus are accessed Press ENTER to scroll through until menu 7 Monitoring is displayed Press the scroll keys to select the input or output the channel number and the point in the signal path...

Страница 29: ...lanced TRS audio cables to interconnect the monitor L and R signals over distances up to 250 metres Take care to run the cables in such a way to avoid damage or interference pickup Using the Monitor as Additional Channels You can use the monitor L and R TRS sockets as additional channel inputs and outputs In the unexpanded iDR 8 these combine with the XLR sockets to provide a 10x10 matrix as shown...

Страница 30: ...rs connect to the same iDR 8 then daisy chain from DR Link OUT on one to DR Link IN on the other Turning the expander on or off Turn the unit on by pressing the rear panel power ON OFF switch The power LED lights up The link LED lights if the DR Link connection is established with the iDR 8 Then the lock LED lights once audio communication is established with the iDR 8 The iDR System Manager detec...

Страница 31: ...uired to connect to the expanders not between the main units Make sure you connect DR Link to the iDR 8 associated with each expander Make sure you plug into the correct DR Link socket In this case do not daisy chain DR Link from one expander to the other Use CAT5 STP cable Maximum cable length is 250 metres Maximum audio matrix is 16x16 The audio link cable carries 8 channels This can provide a d...

Страница 32: ...ate needs to be removed The slave LED lights when the unit is assigned as a slave The ext sync lock LED lights when audio is being correctly synchronised between the units Both LEDs are off if the unit is the master Daisy chained units This example shows two units chained together and including the audio expanders Unit A becomes the sync master Unit B the slave The CAT5 cable between them connects...

Страница 33: ...nually assign one of the units to be the master If this is not done then the operation of the units is unpredictable Do this from within the iDR System Manager session for the unit you want to be the master usually the first in the chain Open the File menu Preferences Synchronisation Options window Tick the Force Sync Master item To avoid feedback oscillation make sure you do not route any output ...

Страница 34: ... Link connection is established with the iDR 8 The iDR System Manager detects the presence of connected iDR switch units Checking for iDR switch expanders You can check to see how many iDR switch units are connected and working from within iDR System Manager by opening up the Soft LEDs or Soft Keys windows Connecting to the iDR 8 The iDR 8 communicates with the iDR switch using the DR Link port Th...

Страница 35: ...at the iDR switch end only If a local ground is not available then use the cable shield to connect the plate to the chassis of the iDR switch unit as shown This is not necessary if the wall plate is made of non conductive material such as plastic which insulates it from the operator Using the switch closure inputs The input is opto coupled to isolate the iDR switch from the connected equipment It ...

Страница 36: ... total isolation between the iDR switch and external equipment Maximum external supply voltage must not exceed 24V DC Maximum current sink through any open collector output must not exceed 200mA A few examples are shown in the diagram here For further advice contact Allen Heath technical support Remote controllers The iDR switch is designed to be used with a wide range of remote control devices in...

Страница 37: ...s dedicated to communicating with third party controllers such as the many touch screens and remote control systems available from other manufacturers Refer to the Allen Heath iDR SysNet Protocol document for details on how to control the parameters using this RS232 interface This can be downloaded from our web site Use standard RS232 cables up to 3 metres 10 feet in length PL Anet This is an RS48...

Страница 38: ... starting point you want If no power up patch has been set then the unit resets all its patch parameters to factory default the same as stored in the RESET configuration file The configuration settings are restored and the patches can be recalled in the normal way iDR 8 unit settings These are the settings which are permanently held in the unit and not archived on the PC They include settings whic...

Страница 39: ...ected You may want to assign this as the power up patch This gives you a known starting point Only store the parameters you need For your working patches decide which parameters should be affected and save only those in the patches That keeps the basic system assignment intact Keep it simple Focus on the needs of the application and avoid the temptation to create complex patch structures Plan the ...

Страница 40: ...D PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING ATTENTION REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES 47 63Hz 25W MAX 100 240V THIS APPARATUS MUST BE EARTHED WARNING SERIAL NUMBER AVIS RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR FUSE T500mAL next OUT DR LINK previous IN IN 10 Complies with UL6500 CSA E65 EN60065 IN 16 IN 15 MIC LINE INPUTS IN 14 IN 13 IN 11 IN 12 I...

Страница 41: ...d sound distribution and control Paging and background music Source routing and mixing Signal equalisation and dynamics processing Automatic microphone mixing Venue speaker management System time alignment DAC OUTPUT OUTPUT ANALOG PHYSICAL OUTPUTS SILENCE 15 16 1 2 MONO STEREO FADER OUTPUT CHANNELS FADER MUTE 48V NAME NAME PEQ4 PINK NOISE 1 3 OCT BP OSCILLATOR WHITE NOISE INPUT L R MONITOR ADC ADC...

Страница 42: ...weighted 112dB unweighted Performance Frequency response 20Hz 20kHz 0 0 5dB Crosstalk 80dB 1kHz 0dB gain THD noise 0 01 1kHz 0dBu Residual output noise 93dBu Input to output noise 0dB gain 87dBu Input to output noise 50dB gain 73dBu Mic Line Inputs x8 x16 expanded Female 3pin XLR Electronically balanced pin 2 hot Impedance 2k ohm pad out 10k ohm pad in Gain range 15 to 50dB in 3dB steps Pad 20dB S...

Страница 43: ...TP cable follows EIA TIA 568B standard Refer to Allen Heath application chart for lengths DR Link Port Serial control of iDR expander units Proprietary Allen Heath control protocol RJ45 connector IN and OUT ports provided on expanders to allow daisy chaining through multiple units CAT5 STP cable up to 300 metres 1000 feet iDR switch Inputs x24 Contact closure to connect pin to ground Opto isolated...

Страница 44: ...aracter grey backlit Assignable display patch related Combinations of clock unit name and user text Setup menu code update and status modes Memory System Up to 99 patches memory usage dependent Patch name up to 8 characters displays on PC can display in LCD Select parameters to save from on screen list Add remove copy paste parameter edit functions Selectable power up patch recall Patch recall ass...

Страница 45: ...isplay level response curve gate active in out and sidechain meters Controls in out sidechain in out Compressor Threshold 48 to 18dBu Ratio variable 1 1 to 1 infinite Knee hard soft Makeup gain 0 to 18dB Attack 300us to 300ms Release 100ms to 2s Auto modes live music AGC vocal speech Display level response curve gain reduction in out sidechain meters time versus reduction histogram Controls in out...

Страница 46: ...0ms Input faders mutes groups Fader levels off Mutes off Group assignments none Group levels 0dB Input patchbay XLR 1 to Channel 1 XLR 8 to Channel 8 Expander 9 to Channel 9 Expander 16 to Channel 16 Output patchbay Channel 1 to XLR 1 Channel 8 to XLR 8 Expander 9 to XLR 9 Expander 16 to XLR 16 LCD Line 1 user text Allen Heath Line 2 time Mic preamps Pad on Gain 20dB resulting gain 0dB 48V off Lim...

Страница 47: ...y Edit the text to identify the key and LED functions maximum of three lines per cell each with eight characters Overall size of each label is 187 x 13 mm Insert the labels into the iDR 8 front face plate between the plastic LED facias and the metal face plate Once fitted the labels are protected by the face plate plastic windows 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 ...

Страница 48: ...48 IDR 8 User Guide ...

Отзывы: