Rear Panel Overview
1
Mains input
Use the IEC lead with moulded
mains plug suitable for your local mains voltage.
The protection fuse rating is marked on the rear
panel. The on/off switch is positioned on the rear
panel to prevent accidental operation.
2
Network port
RJ45 socket for connection to
an Ethernet network or PC using UTP CAT5 cable.
This port is recommended for configuring the
system with iDR software. The MDI/X switch
selects network or direct to PC operation. The link
LED lights when communication is established.
The TX LED lights when data is communicated.
Note:
The RS232, MIDI, SysNet and PL-Anet
control ports are not all available at the same time.
A combination of two is selected using iDR
System Manager. The associated active LED
lights when the port is available.
3
RS232 (MODEM) port
This is used for
connection to a modem so that the unit can be
interrogated by a remote PC over a standard
telephone line. It can also be used for system
configuration using iDR System Manager software
but the faster network port is recommended.
Pressing the front panel switch selects either the
front or rear RS232 port.
4
MIDI port
Standard opto-isolated MIDI port
with IN, THRU and OUT connectors.
5
SysNet port
An RS232 serial port for
communication with third party remote controllers
running the Allen & Heath SysNet protocol.
6
PL-Anet port
An RS485 serial port for
communication with a network of Allen & Heath
PL wall plates and remote controllers using CAT5
STP cable.
7
DR-Link port
RJ45 socket for control of iDR
audio and logic expander units using CAT5 STP
cable. IN and OUT ports are provided on the
expander units so that the control can be daisy
chained through a system with more than one
expander.
8
Audio expander ports
RJ45 sockets for
communicating 8 channel digital audio between
the
iDR-8
and its expanders using CAT5 STP
cable. Two cables are required between the
expander and
iDR-8
, one for the audio, the other
for DR-Link control.
9
Mic/Line inputs
Balanced XLR inputs for
microphone and line level sources. Adding the
iDR-in
expands the
iDR-8
to 16 inputs.
10
Audio outputs
Balanced XLR line level
outputs with m18dBu level. Adding the
iDR-out
expands the
iDR-8
to 16 outputs.
11
Monitor inputs and outputs
Balanced TRS
jacks for L and R monitor inputs and outputs.
These provide a line level version of the front
panel stereo headphones output and can daisy
chain through multiple iDR units.
12
Switch closure inputs
These are provided
on the
iDR-switch
. They can be hard wired from
remote wall plate and controller switches and
relays.
13
Open collector logic outputs
These are
provided on the
iDR-switch
. They can be used to
control LEDs, lamps, relays and other devices.
14
Earth terminals
These are provided to earth
(ground) the switch and logic output cable
shields.
Use null-modem cable to connect to PC com port
CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN.
FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING.
ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES.
THIS APPARATUS MUST BE EARTHED.
WARNING
47-63Hz ~ 90W MAX
100 - 240V~
active
RS232 (MODEM)
Complies with UL6500, CSA-E65, EN60065
MONITOR OUT
LINK
TX
Refer to user guide for port selection details
FUSE: T1.6AL
AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.
SERIAL NUMBER
Made in the UK by ALLEN&HEATH LIMITED
MONITOR IN
DIGITAL EXPANDER
R
PL-ANET
DR-LINK
L
R
AUDIO OUT
AUDIO IN
THRU
active
MDI/X
NETWORK
MIDI OUT
active
MIDI IN
active
SYSNET PORT
L
OUT 8
OUT 7
OUT 5
LINE OUTPUTS
OUT 6
OUT 4
IN 8
IN 7
IN 5
MIC/LINE INPUTS
IN 6
IN 4
OUT 3
OUT 2
OUT 1
IN 3
IN 2
IN 1
Made in the UK by ALLEN&HEATH LIMITED
AUDIO OUT
CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN.
FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING.
ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES.
47-63Hz ~ 25W MAX
100 - 240V~
THIS APPARATUS MUST BE EARTHED.
WARNING
SERIAL NUMBER
AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.
FUSE: T500mAL
next
OUT DR-LINK
previous
IN
IN 10
Complies with UL6500, CSA-E65, EN60065
IN 16
IN 15
MIC/LINE INPUTS
IN 14
IN 13
IN 11
IN 12
IN 9
AUDIO IN
Made in the UK by ALLEN&HEATH LIMITED
CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN.
FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING.
ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES.
THIS APPARATUS MUST BE EARTHED.
WARNING
47-63Hz ~ 25W MAX
100 - 240V~
SERIAL NUMBER
FUSE: T500mAL
AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.
next
OUT DR-LINK
previous
IN
OUT 10
Complies with UL6500, CSA-E65, EN60065
OUT 16
OUT 15
LINE OUTPUTS
OUT 14
OUT 13
OUT 11
OUT 12
OUT 9
V
G
G
4
3
2
1
G
5
6
7
8
G
12 11 10 9
G
13
14
15
16
G
20 19 18 17
G
21
22
23
24
SWITCH INPUTS
LOGIC OUTPUTS
1
2
3
+
-
4
V
G
V
G
V
G
+
- +
- +
-
5
6
7
+
-
8
+
- +
- +
-
9
10
+
- +
- +
- +
-
11
12
14
+
- +
- +
- +
-
15
16
13
switch
G
opto
+10V
2K2
opto
+
-
V
G
+10V DC max total 500mA
open collector
+24V DC, 200mA max
+10V
FUSE: T500mAL
WARNING
THIS APPARATUS MUST BE EARTHED.
ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES.
FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING.
100 - 240V~
47-63Hz ~ 15W MAX
CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN. AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.
Made in the UK by ALLEN&HEATH LIMITED
Complies with UL6500, CSA-E65, EN60065
OUT
IN
DR-LINK
next
previous
TO AVOID DAMAGE ONLY CONNECT
CAUTION 20V DC
COMPATIBLE REMOTE CONTROL
EQUIPMENT TO THE PL-ANET PORT.
DIGITAL EXPANDER
DIGITAL EXPANDER
Содержание iDR-8
Страница 48: ...48 IDR 8 User Guide ...