background image

To ensure your new pond filter system is set up and running correctly, and to 

prevent any accidental damage or injury, please read and follow the below 

instructions carefully before using your product.

 

SAFETY

IMPORTANT!

 

Disconnect the mains electricity supply before attempting any 

installation / maintenance of any kind. Do not attempt to modify this unit in 
any way and only use the recommended parts for replacement.

·    

 

The all-in-one CUP system should never be run dry as this will cause the 

unit to overheat and cause permanent damage.

·     

All connections must be earthed.

·     

The power cord of this appliance cannot be replaced; if the cord is 

damaged, the appliance should be discarded. Never cut the cord.

·      

Do not connect to any voltage other than that stated.

·      

Do not place in liquids other than water.

·      

Do not use with water above 90 F or 30 C.

°

°

·      

Do not carry or pull the unit by its electrical cable.

·      

Do not use this unit if it has a damaged cord, if it is malfunctioning or it is 

dropped or damaged in any manner

·      

Do not attempt to modify this unit in any way and only use attachments and 

the recommended parts for replacement recommended by the 
manufacturer.

·      

Before installing, maintaining or handling your equipment, or before placing 

your hands in your pond, ensure that the unit is disconnected from the 
electricity supply.

·      

Always disconnect any electrical devices when not in use.

·      

Carefully examine your pond system after installation. Do not connect the 

unit to the mains if there is water on any parts not intended to be wet. 

·      

Do not look directly at the UV light when it is operational.

·      

Before operating your CUP system observe that  water is flowing through it 

- the UV requires constant flow to avoid overheating.

Содержание CUP-7000

Страница 1: ...V CLARIFICATION 5200 LITRES PER HOUR PUMP QUICK RELEASE CASING FOR EASY MAINTENANCE INCLUDES COARSE MEDIUM FILTER FOAMS BIOLOGICAL FILTER MEDIA CLEAN AND CLEAR WATER FOR HEALTHY FISH ADDITIONAL MEDIA...

Страница 2: ...Do not place in liquids other than water Do not use with water above 90 F or 30 C Do not carry or pull the unit by its electrical cable Do not use this unit if it has a damaged cord if it is malfuncti...

Страница 3: ...a ensuring all water has been drained from the lter Do not bury the cord for this unit Ensure it does not cause a trip hazard or it at risk from damage from lawn mowers strimmers or other garden equip...

Страница 4: ...wiring A residential current device RCD is used for additional safety You have complied with Local Electricity Authority regulations if permanently installing to the mains supply Please Ensure The pow...

Страница 5: ...hments Choose the required attachments Fountain attachment set included compromises of Main fountain extendable pole essential for using the fountain feature Hosetail nozzle to t 20mm and 25mm hose 2...

Страница 6: ...your warranty We recommend that a regular cleaning and maintenance schedule is followed to ensure responsible shkeeping Depending on water volume and stocking levels regular cleaning of the lter medi...

Страница 7: ...ou have How often you feed your sh and seasonal light levels will also a ect how quickly your pond water gets dirty and will need to be taken into consideration when planning how often to clean your l...

Страница 8: ...neral Maintenance It is recommended that every 3 4 weeks you perform maintenance on the CUP 7000 Impeller untwist the uv steriliser connector to separate it from the pump The impeller can be accessed...

Страница 9: ...of operation when the lter is slowly being colonised The quartz sleeve can be coated in limescale build up in hard water areas This should be carefully removed from the quartz sleeve and cleaned with...

Страница 10: ...ing free of unit IMPORTANT The replacement does not require removal of the gold outer shell protecting the bulb The top of the gold outer shell has sharp edge DO NOT touch this part 3 You can now repl...

Страница 11: ...NNECTOR 10 COARSE SPONGE 11 FINE SPONGE 12 SPONGE FILTER CAGE 13 O RING 2 14 5 WATER FLOW ADJUSTER 15 CERAMIC MEDIA 16 FILTER BODY 17 PUMP 18 FILTER MEDIA PLATE 19 5 DIVIDER 20 O RING 3 24 UV CLARIFIE...

Страница 12: ...e the glow of the bulb through this 4 If the above does not solve the issue replace the UV bulb 5 Please check for signs of damage or water ingress to quartz sleeve and bulb area You might need to rep...

Страница 13: ...th facing gardens inevitably get more sunlight and can cause ponds to be greener in the summer if exposed all day Try and shade your pond water surface plants are a great way to do this In order to co...

Страница 14: ...ctly on the bottom on the pond This is to prevent large clumps of debris blocking the inlets and restricting the ow 2 Inspect the quartz sleeve for hair line cracks and ensure that all O rings are in...

Страница 15: ...ONDS WITH SUITABLE FOR UP TO 7000L UP TO 4000L OUTLET FITS DIMENSIONS LxWxH mm MAX HEIGHT cm MAX FLOW RATE MODEL CUP 7000 480 350 x 310 x 198 5200 L H WATTAGE 55w CABLE LENGTH 10m Plug not included VO...

Страница 16: ...UV bulbs are not covered by your warranty and a charge may be required for replacements of these This warranty does not apply to any unit that has been subjected to misuse accidental damage negligenc...

Страница 17: ......

Страница 18: ...www allpondsolutions co uk All Pet Solutions Limited Trading as All Pond Solutions Unit 203 Riverside Way Uxbridge Middlesex England UB8 2YF...

Отзывы: