To access quartz sleeve loosen it up by inserting a flathead screwdriver
between the quartz sleeve and quartz sleeve hosing (see reference image
below). Gently pull it out to remove it.
Clean body and all attachments. Reassemble.
Adding All Pond Solutions Filter Start Bacteria
Treatment after filter maintenance will help replenish
beneficial populations of bacteria and is highly recommended during the first
two months of operation when the filter is slowly being colonised.
The quartz sleeve can be coated in limescale build
up in hard water areas. This should be carefully
removed from the quartz sleeve and cleaned with a
soft cloth.
Quartz sleeve & UV bulb
-
remove the UV clarifier from the unit by
unscrewing four screws (as shown in the image below). To access UV bulb
unfasten the clip located on the side. Gently rotate the housing to remove it.
When reassembling your unit you must make sure
the black O-ring sits on top of the quartz sleeve (as
seen in the image on the right). This will enable you
to correctly reattach the ballast.