battery powered torque multiplier

 

 

Always place the  

STACO/STABI 

completely and safely 

on the bolt/nut. The support of the 

DMA

 to absorb 

the reaction torque must always be safe and stable. 

Please consult your 

alkitronic® partner

 for custom-

ized 

DMA

 solutions.

  

 

  An incomplete or incorrect connection or support 

will lead to the following when bolting:

 

 

-   Possible overload fractures of the 

STACO / STABI

  

  gear and even drive square 

 

 

-  Incorrect torque application 

 

-  

-  Contusions or severe injuries caused by spun off  

  parts or splinters.

• 

An improper usage may also render all warranties null and 

void.

  

Incorrect

correct

Correct support 

point only in the 

marked area

Incorrect

6. Mechanical operation

6.1 

Safety instructions for tightening and loosening

 

 

Always observe local regulations and directives 

when starting the tool. Always inspect power tool 

as to its function and safety condition – never work 

with damages tools or objects!

 

  Beware freely rotating accessories (

alkitronic®  

DMA / STACO / STABI

). Loose garments, long 

hair, cables etc. must be kept outside the danger  

zone / rotation range.

 

 The

 

alkitronic®

 

EAF

 torque multiplier must never 

be operated without supervision. An immediate 

stopping must be possible at all times. Observe 

safety distances. 

  

6.1.1  Tightening and loosening

Work steps

• 

 Place 

alkitronic® EAF 

with 

STACO / STABI

 onto the bolt / 

nut.

• 

 The 

DMA

 must absorb the reaction torque on the level 

of the 

STACO / STABI

 (S); a stable abutment (G) must be 

provided.

• 

 Always hold the torque multiplier perpendicular over 

the bolt axis.

• 

Start bolting action.

• 

The tool will stop as soon as the set shut-off torque or 

entered value has been reached.

G

S

  

 

Never reach between 

DMA

 and support point. High 

risk of injuries (contusion)!

Direction of rotation 

tightening

Reaction torque

Do not retighten bolts/nuts! Because the pre-

set torque is exceeded and it can lead to dam-

age to the torque multiplier or to the screw /

threaded bolt.

alkitronic®

 

EAF 

model - before moving to the next bolt / nut:

Various torque multipliers from other manufacturers cannot 

be removed from the bolt joint (torsional force). 

 

No problem for the 

alkitronic® EAF

 model, with 

integrated, fully-automatic release function. This 

function enables a fast, secure “run free“ of the reac-

tion arm (

DMA

) and also relieves torsional stresses 

within the multiplier.

For Information:

When loosening the bolted connection, up to 20% higher 

torque (loosening torque) may be required. 

• 

Switch off motor

• 

Remove machine, place on next bolt/nut

• 

Start bolting process

Содержание EAF

Страница 1: ...Operation and Maintenance Manual Battery powered torque multiplier EAF...

Страница 2: ...not only the general safety notices and warnings listed in this section Identification of Notices but also all generally applicable regulations directives and warnings Identification of Notices Safety...

Страница 3: ...Nuts bolts are tightened or loosened with a high torque and when a set value or required final torque value is reached themachineisswitchedoff Thedeviceisdrivenwith a maintenance free low wear brushle...

Страница 4: ...station has been dimensioned exclusively for charging alkitronic Li Ion rechargeable battery packs Any other use is considered improper any damages resulting from improper use are the responsibility...

Страница 5: ...is defective Immedi ately remove the battery pack from the charger 2 3 Hazard notices In case of mechanical or electrical damages to the alkitronic EAF Li Ion rechargeable battery pack or the alktroni...

Страница 6: ...at of the charger Push the battery pack into the battery seat of the power tool all the way 7 until the safety catch locks audibly 4 1 2 Battery pack capacity and signal display Push button 8 on the b...

Страница 7: ...ry This washer prevents a loosening of the DMA and can be pushed over the gear cogs and screwed tight 9 DMA safety screw DMAR safety washer accessory alkitronic DMA Place the alkitronic EAF on a flat...

Страница 8: ...the slide switch to the middle Gear 1 Gear 2 In order to optimize the bolt ingcycleitisrecommendedto start in gear 2 fast and then depending on the required torqueswitchtogear1 powergear untilthestopp...

Страница 9: ...ion An immediate stopping must be possible at all times Observe safety distances 6 1 1 Tightening and loosening Work steps Place alkitronic EAF with STACO STABI onto the bolt nut The DMA must absorb t...

Страница 10: ...ng gear noise or obvious severe damage an immediate repair is necessary Please sendall devicesto be repaired in their originalpackagingtoyournearestalkitronic partner or to alki TECHNIK GmbH 8 Servici...

Страница 11: ...e g cover with PTFE 9 2 Causes and problem solving Battery pack almost empty The electronic system protects the battery pack against complete discharging If the LED display L Fig 4 flashes the batter...

Страница 12: ...r approx D1 mm 41 41 54 54 72 72 72 Diameter approx D2 mm 85 85 85 85 93 93 109 Diameter approx D3 mm 88 88 88 88 97 97 109 Length approx L mm 295 295 320 350 370 370 380 Weight without DMA approx kg...

Страница 13: ...ter approx D3 mm 88 97 97 109 Height approx H mm 305 310 320 330 Weight without DMA approx kg 9 5 9 5 11 2 11 0 Idle speed Gear 1 U min 1 7 1 5 1 0 0 8 Idle speed Gear 2 U min 6 0 5 0 4 0 3 0 When loo...

Страница 14: ...14 Operating and service manual Notes...

Страница 15: ...15 battery powered torque multiplier Notes...

Страница 16: ...ductivity Quicker tightening without reworking No environmentally caused failures IP54 ATEX High work safety Easy to use clear simple instructions Low maintenance and cost efficient Increased precisio...