10.  Declaration of conformity 

Alke  B.V.,  located  in  Scherpenzeel,  The  Netherlands,  hereby  declares  that  the  AL-series,  marked  on  their 
dataplates with CE and with CE approval/production supervision by Kiwa (number 0063) are in compliance with 
the following EU legislation: 
 

Regulation on appliances burning gaseous fuels (GAR) 2016/426/EU 

Low Voltage Directive (LVD) 2014/35/EU (models with electric components) 

EMC Directive (EMC) 2014/30/EU (models with electric components) 

 
Scherpenzeel, 01-03-2019 

 

Adri van Alphen  
President 
 

11.  Technical table (see next page) 

Read the technical table for gas related information.  
 
The combination category, gas group, gas supply pressure and countries of destination are selected with the 
help of the European standards EN 419 and EN 437. These standards give the official situation per country. 
But their listing is not always complete and sometimes unclear and in contradiction with each other. In some 
countries  the  situation  locally  can  be  different  from  the  official  information  or  the  information  is  even  not 
available. Our advice is to stay first with the official listing as given in the table below. In other cases, check with 
the local gas authorities the data plate of the heater to determine if the heater can be used safely in the specific 
situation. 
 

Information for K-gas only (G25.3)

 

I

2EK

. Gas G25.3: This appliance is adjusted for the appliance category K (I

2K

) and is suitable for use of G and 

G+  distribution  gases  according  the  specifications  as  written  down  in  the  NTA  8837:2012  Annex  D  with  a 
Wobbe-index of 43,46 

– 45,3 MJ/m

3

 (dry, gross, 0°C) or 41,23 

– 42,98 MJ/m

3

 (dry, gross, 15 °C). 

 
This appliance also can be adjusted or converted to the appliance category E (I

2E

) gas G20 and in that case, it 

is suitable to use high calorific distribution gases with a Wobbe-index of 49,4 

– 51,4 MJ/m

3

 (dry, gross, 15 °C). 

Precondition for the high calorific distribution gas is that the composition contains no more than 7% propane, 
12% ethane, 1.5% carbon dioxide, 0.5% hydrogen and 1.8% water vapor, with the total PE number (propane 
equivalent) not higher than 7 %. 
 
The above limit values for the Wobbe index are the values guaranteed by the EN419 standard tests with the 
extreme limit gases applicable to the mentioned appliance categories. 
 
 
 

Содержание AL-4 Series

Страница 1: ...L 7 Series Atmospheric ceramic gas infrared heaters for outdoor use Country of destination GB IE MT General international manual AL 7 SEi AS AL 4 F AS AL 6 FSEi AS Alke BV Industrielaan 11a 3925 BD Sc...

Страница 2: ...Version 2 March 2020 2 manual 0009 0231EN Fig 1a Fig 1b Fig 1c Fig 1d Fig 2a Fig 2b Fig 3a Fig 3b Fig 4 Fig 5a Fig 5b Fig 5c Fig 6...

Страница 3: ...the system is safe again Consult an installer If a heater is not safe to use anymore close the gas supply and electricity to the heater so that nobody accidentally can operate the heater Contact a ser...

Страница 4: ...dealer in case the carton box and heater are damaged Before leaving the factory all the heaters are operated and tested by the manufacturer on gas for 5 minutes Note that due to this the burner and re...

Страница 5: ...space The heaters are intended for outdoor use only or amply ventilated areas but not for indoor heating See fig 1a 1b 1c When local regulations allow it there are no safety objections to use the heat...

Страница 6: ...objects Ventilation around the heater Check if there is sufficient space for the combustion gases to vent away but also if there is enough fresh air available at the inlet of the venturi 10 or 33 to t...

Страница 7: ...connections of the gas regulator and the gas valve of the gas cylinder are of the same type Check with the gas cylinder supplier for the correct size of gas regulator and check whether the capacity is...

Страница 8: ...er try to do gas repairs by yourself Do not use the heater anymore until the problem is solved 5 Electrical information only heaters with S Ei or SEi as a part of the model identification General All...

Страница 9: ...h fire To do so the gas pressure shall be adjusted at maximum nominal pressure as indicated on the data plate solenoid valves shall be in open or high fire position If desired the heat input of the he...

Страница 10: ...olenoid valve S How to check correct operation of the burner Directly after ignition the burner flames are blue difficult to see during daylight After 15 seconds the ceramic burner stone starts glowin...

Страница 11: ...metal spark wire and earthing wire still makes a 90 degrees angle directly above the ceramics and are not bending away to larger angles Clean the ignition device and check the connection of the igniti...

Страница 12: ...ts by new ones Use a proper gas sealant to avoid gas leakage and seal the new parts Check the gas supply for the proper gas pressure and gas type and do a leakage test first Take the heater into opera...

Страница 13: ...m Thermocouple and or magnetic coil of the safety device are broken Gas pressure lower than minimum requested Heater not suspended at 45 degrees angle facing downwards Not all burner stones are ignite...

Страница 14: ...del you have For spare parts service material advice and information please contact the distributor Always mention the model name and serial number Service parts are only available via the distributor...

Страница 15: ...Version 2 March 2020 15 manual 0009 0231EN Overview Parts AL 6...

Страница 16: ...Version 2 March 2020 16 manual 0009 0231EN Overview Parts AL 7...

Страница 17: ...15 Gas injection set AL 4 FSEi 10001013 10001023 10001033 10001043 10001053 10001063 10001073 Gas injection set AL 6 FSEi 10001113 10001123 10001133 10001143 10001153 10001163 10001173 Gas injection s...

Страница 18: ...tion or the information is even not available Our advice is to stay first with the official listing as given in the table below In other cases check with the local gas authorities the data plate of th...

Страница 19: ...1 60 1 60 2 00 15 37mm 5 0063CT3446 2K 2L G25 3 200 100 5 40 3 80 0 59 m3 h 1 00 1 00 1 00 10 5 37mm 5 0063CT3446 3P G31 50 25 4 50 3 20 322 g h 0 97 0 97 0 97 18 37mm 5 0063CT3446 3P G31 150 75 4 75...

Страница 20: ...Version 2 March 2020 20 manual 0009 0231EN The local distributor...

Отзывы: