8.  Fault finding 

Trouble 

Cause 

Burner does not light. 
Spark is available

 

• 

The gas valve of the gas cylinder (or gas line) is not open 

• 

Gas cylinder is empty 

• 

Air in the (new) gas lines 

• 

Gas injector is blocked 

• 

Gas pressure/gas quality is not corresponding with the data plate info 

• 

The burner is not on high-fire setting during ignition 

• 

The (optional) solenoid valve S is not connected or is damaged 

• 

During sparking manual ignition is possible with a lighter: check the location of 
the spark gap related to the ceramic stone is correct 

• 

Gas safety device does not open with a 

“click” during ignition period, the Ei coil 

is broken. Replace. 

Burner does not light. 
No spark available 

• 

No 230 Volt available at the Ei 

• 

Spark electrode line is not connected to the Ei 

• 

Spark electrode gap incorrect. Shall be between 3-4 mm 

• 

Spark jumps off to other metal parts before the spark electrode. Check wire, 
connectors and ignitor ceramics. Check if parts are dry 

• 

Ignition loop is not complete. Check the ignition wire and earthing wire 

• 

Ignitor Ei is broken. Replace 

• 

Ei is in recovery phase. Leave the Ei connected to 230V for 20 minutes to reset 
and try again 

Burner extinguishes after lighting

 

• 

Keep button safety device pressed for a longer period (up till 25 seconds) 

• 

Position of the thermocouple is wrong (see above) 

• 

Thermocouple nuts are not connected properly to the gas safety device and to 
the Ei unit, or the nuts are loose 

• 

Thermocouple is not heated by the flame or not mounted properly 

• 

Thermocouple switch in Ei is broken. Check (after switching 230V to the Ei) by 
multi 

meter if resistance of the internal switch is <25 mΩ 

• 

Thermocouple and/or magnetic coil of the safety device are broken.  

• 

Gas pressure lower than minimum requested  

• 

Heater not suspended at 45 degrees angle (facing downwards) 

• 

Not all burner stones are ignited, especially near the thermocouple 

Flames:

 

- leave the confines of the burner 
- or are sooting 
- or a blue cloud is under the 
reflector 

 

• 

Gas pressure is too high. Check the gas pressure with the data plate 

• 

Gas pressure regulator is broken 

• 

Wrong gas. Check data plate for the correct gas supply 

• 

Venturi/air inlet is blocked/dirty  

• 

Venturi and injector wrong. Check with the technical table 

• 

Not enough fresh air available due to mounting situation 

• 

Air filter is dirty  

• 

Heater not suspended at 45 degrees angle 

The burner is only partly glowing 

 

• 

Wrong gas or gas pressure. Check data plate for the gas supply information  

• 

Injector or venturi are blocked or dirty  

• 

Injector and venture size are wrong. Check with the technical table  

• 

Pipe sizes or gas hoses have insufficient capacity  

• 

Setting of the thermostat is wrong 

The burner makes a lot of noise 
after ignition or after several 
minutes 

 

• 

Wrong gas. Check data plate for the gas supply information  

• 

Burner stone is damaged, the flame burns inside the burner house 

• 

A zoom noise of the Ei is created by magnetic fields and lasts only 30 seconds. 
Not harmful and temperature dependent. Turn the Ei in another position. 

The burner does not work at 
minimum heat input

 

• 

Gas pressure is not correct. Check the gas pressure with the data plate 

• 

Wrong gas. Check data plate for the correct gas supply  

• 

Size of the venturi and injector is wrong. Check with the technical table  

• 

By-pass hole solenoid valve (S) is blocked 

• 

Injector (partly) blocked 

• 

Thermocouple has not the proper location to the ceramic burner 

Heater will not attain the desired 
temperature 

 

• 

The solenoid valve (S) is not functioning 

• 

Injector partly blocked 

Содержание AL-4 Series

Страница 1: ...L 7 Series Atmospheric ceramic gas infrared heaters for outdoor use Country of destination GB IE MT General international manual AL 7 SEi AS AL 4 F AS AL 6 FSEi AS Alke BV Industrielaan 11a 3925 BD Sc...

Страница 2: ...Version 2 March 2020 2 manual 0009 0231EN Fig 1a Fig 1b Fig 1c Fig 1d Fig 2a Fig 2b Fig 3a Fig 3b Fig 4 Fig 5a Fig 5b Fig 5c Fig 6...

Страница 3: ...the system is safe again Consult an installer If a heater is not safe to use anymore close the gas supply and electricity to the heater so that nobody accidentally can operate the heater Contact a ser...

Страница 4: ...dealer in case the carton box and heater are damaged Before leaving the factory all the heaters are operated and tested by the manufacturer on gas for 5 minutes Note that due to this the burner and re...

Страница 5: ...space The heaters are intended for outdoor use only or amply ventilated areas but not for indoor heating See fig 1a 1b 1c When local regulations allow it there are no safety objections to use the heat...

Страница 6: ...objects Ventilation around the heater Check if there is sufficient space for the combustion gases to vent away but also if there is enough fresh air available at the inlet of the venturi 10 or 33 to t...

Страница 7: ...connections of the gas regulator and the gas valve of the gas cylinder are of the same type Check with the gas cylinder supplier for the correct size of gas regulator and check whether the capacity is...

Страница 8: ...er try to do gas repairs by yourself Do not use the heater anymore until the problem is solved 5 Electrical information only heaters with S Ei or SEi as a part of the model identification General All...

Страница 9: ...h fire To do so the gas pressure shall be adjusted at maximum nominal pressure as indicated on the data plate solenoid valves shall be in open or high fire position If desired the heat input of the he...

Страница 10: ...olenoid valve S How to check correct operation of the burner Directly after ignition the burner flames are blue difficult to see during daylight After 15 seconds the ceramic burner stone starts glowin...

Страница 11: ...metal spark wire and earthing wire still makes a 90 degrees angle directly above the ceramics and are not bending away to larger angles Clean the ignition device and check the connection of the igniti...

Страница 12: ...ts by new ones Use a proper gas sealant to avoid gas leakage and seal the new parts Check the gas supply for the proper gas pressure and gas type and do a leakage test first Take the heater into opera...

Страница 13: ...m Thermocouple and or magnetic coil of the safety device are broken Gas pressure lower than minimum requested Heater not suspended at 45 degrees angle facing downwards Not all burner stones are ignite...

Страница 14: ...del you have For spare parts service material advice and information please contact the distributor Always mention the model name and serial number Service parts are only available via the distributor...

Страница 15: ...Version 2 March 2020 15 manual 0009 0231EN Overview Parts AL 6...

Страница 16: ...Version 2 March 2020 16 manual 0009 0231EN Overview Parts AL 7...

Страница 17: ...15 Gas injection set AL 4 FSEi 10001013 10001023 10001033 10001043 10001053 10001063 10001073 Gas injection set AL 6 FSEi 10001113 10001123 10001133 10001143 10001153 10001163 10001173 Gas injection s...

Страница 18: ...tion or the information is even not available Our advice is to stay first with the official listing as given in the table below In other cases check with the local gas authorities the data plate of th...

Страница 19: ...1 60 1 60 2 00 15 37mm 5 0063CT3446 2K 2L G25 3 200 100 5 40 3 80 0 59 m3 h 1 00 1 00 1 00 10 5 37mm 5 0063CT3446 3P G31 50 25 4 50 3 20 322 g h 0 97 0 97 0 97 18 37mm 5 0063CT3446 3P G31 150 75 4 75...

Страница 20: ...Version 2 March 2020 20 manual 0009 0231EN The local distributor...

Отзывы: