54
Alternatively you can search options by the following:
By Type
,
By Time
or
By Type&Time
By Type
This option displays log information according to the assigned type.
The type is divided into either Major Type or Minor Type. Major Type
includes
Operation
,
Alarm
,
Exception
and
All
. Each Major Type includes a
number of Minor Types, so you can select either a Major Type or a subset
within a Major Type classed as a Minor Type.
Operation
This includes the following minor types:
Power On, Shut Down, Abnormal Shut, Panel Login, Panel Logout, Panel
Config, Panel File Play, Panel Time Play, Local Start Record, Local Stop
Record, Panel PTZ, Panel Preview, Panel Set Time, Local Upgrade, Net Login,
Net Logout, Net Start Record, Net Start Transparent Channel, Net Stop
Transparent Channel, Net Get Parameter, Net Config, Net Get Status, Net
Alert On, Net Alert Off, Net Reboot, BiComStart (Start Voice Talk), Net
Upgrade, Net File Play, Net Time Play, Net PTZ.
Alarm
This includes the following minor types:
External Alarm In, External Alarm Out, Motion Detect Start, Motion Detect
Stop, View Tamper Start, View Tamper Stop.
Exception
This includes the following minor types:
Video Signal Loss, Illegal Access, Hard Disk Error, Hard Disk Full, IP
Conflict, DCD Lost.
Example - Viewing the Alarm Log.
1.
At Query select By Type.
2.
For Major Type select Alarm and for Minor Type select one of the
following:
3.
External Alarm In, External Alarm Out, Motion Detect Start, Motion
Detect Stop, View Tamper Start, View Tamper Stop.
4.
Press the SearchLog button and then press Enter to start searching.
5.
When search is completed DVR will list all matched alarm information.
In the List box the following information is included:
Index, Occur Time, Major Type, Minor Type, Panel User, Net User,
Host Address, Para. Type, Channel No., HDD No., Alarm In and
Alarm Out. You can also select the MoreInfo option and page number
to show more information.
6.
Press Return button to return to the Utilities menu.