![Alien MAX316 Скачать руководство пользователя страница 112](http://html1.mh-extra.com/html/alien/max316/max316_user-manual_2896791112.webp)
ALIEN MEGA/MAX USER MANUAL
112
Choose one day of the week and up to 8 time periods can be set within each
day. Click
Apply
to save the settings. Time periods must not be duplicated or
overlap.
Repeat the above steps to set up arming schedule for other days of a the week.
You can also use the
Copy
button to copy an arming schedule to other days.
3)
Select
Linkage Action
tab to set up alarm response actions of the alarm input
(please refer to
Setting Alarm Response Actions later in this chapter
).
4)
Click the
OK
button to complete the VCA alarm settings for the channel.
6.
Configure the region and other settings for the selected VCA detection.
Task1: Configure the Line Crossing Detection.
1)
Select the virtual line from the drop-down list. Up to 4 lines are selectable.
2)
Select the direction to A<->B, A->B or A<-B.
Figure 8.5.4 Set Direction of Line Crossing Detection
3)
Set the sensitivity of the line crossing detection between 1-100.
4)
Click
and set two points in the preview window to draw a virtual line.
Figure 8.5.5 Draw Virtual Line in the Image
You can use the
to clear the existing virtual line and re-draw it.
5)
Click
Apply