![Alied Telesis GS970M/10 Скачать руководство пользователя страница 521](http://html1.mh-extra.com/html/alied-telesis/gs970m-10/gs970m-10_command-reference-manual_2896773521.webp)
C613-50163-01 Rev C
Command Reference for GS970M Series
521
AlliedWare Plus™ Operating System - Version 5.4.7-0.x
S
PANNING
T
REE
C
OMMANDS
SPANNING
-
TREE
ERRDISABLE
-
TIMEOUT
ENABLE
spanning-tree errdisable-timeout enable
Overview
Use this command to enable the errdisable-timeout facility, which sets a timeout
for ports that are disabled due to the BPDU guard feature.
Use this command for RSTP or MSTP.
Use the
no
variant of this command to disable the errdisable-timeout facility.
Syntax
spanning-tree errdisable-timeout enable
no spanning-tree errdisable-timeout enable
Default
By default, the errdisable-timeout is disabled.
Mode
Global Configuration
Usage
The BPDU guard feature shuts down the port on receiving a BPDU on a
BPDU-guard enabled port. This command associates a timer with the feature such
that the port is re- enabled without manual intervention after a set interval. This
interval can be configured by the user using the
spanning-tree errdisable-timeout
command.
Example
awplus#
configure terminal
awplus(config)#
spanning-tree errdisable-timeout enable
Related
Commands