C613-50163-01 Rev C
Command Reference for GS970M Series
260
AlliedWare Plus™ Operating System - Version 5.4.7-0.x
P
LUGGABLES
AND
C
ABLING
C
OMMANDS
SHOW
SYSTEM
PLUGGABLE
DIAGNOSTICS
Output
Figure 8-5:
Example output from the
show system pluggable diagnostics
command on a device
Related
Commands
awplus#show system pluggable diagnostics
System Pluggable Information Diagnostics
Port1.0.9 Status Alarms Warnings
Reading Alarm Max Min Warning Max Min
Temp: (Degrees C) 31.105 - 78.00 -13.00 - 73.000 -8.000
Vcc: (Volts) 3.283 - 3.800 2.800 - 3.500 3.100
Tx Bias: (mA) - Low 15.440 0.440 Low -12.440 2.440
Tx Power: (mW) 0.357 Low 1.175 0.200 Low 0.933 0.251
Rx Power: (mW) - Low 1.259 0.049 Low 1.000 0.062
Rx LOS: Rx Down
Table 9:
Parameters in the output from the
show system pluggables
diagnostics
command
Parameter
Description
Temp (Degrees C)
Shows the temperature inside the transceiver.
Vcc (Volts)
Shows voltage supplied to the transceiver.
Tx Bias (mA)
Shows current to the Laser Diode in the transceiver.
Tx Power (mW)
Shows the amount of light transmitted from the transceiver.
Rx Power (mW)
Shows the amount of light received in the transceiver.
Rx LOS
Rx Loss of Signal. This indicates whether:
•
light is being received (Rx Up) and therefore the link is up,
or
•
light is not being received (Rx Down) and therefore the
link is down