log monitor exclude
Overview
Use this command to prevent specified log messages from being displayed on a
terminal, when
is enabled. You can exclude messages on the
basis of:
•
the priority/severity of the message
•
the program that generated the message
•
the logging facility used
•
a sub-string within the message, or
•
a combination of some or all of these.
Use the
no
variant of this command to stop excluding the specified messages.
Syntax
log console exclude [level
<level>
] [program
<program-name>
]
[facility
<facility>
] [msgtext
<text-string>
]
no log console exclude [level
<level>
] [program
<program-name>
]
[facility
<facility>
] [msgtext
<text-string>
]
Parameter
Description
level
Exclude messages of the specified severity level.
<
level
>
The severity level to exclude. The level can be specified as one of the following numbers or
level names, where 0 is the highest severity and 7 is the lowest severity:
0|emergencies
System is unusable
1|alerts
Action must be taken immediately
2|critical
Critical conditions
3|errors
Error conditions
4|warnings
Warning conditions
5|notices
Normal, but significant, conditions
6|informational
Informational messages
7|debugging
Debug-level messages
program
Exclude messages from a specified program.
<
program-
name
>
The name of a program. Either one of the following predefined program names (not
case-sensitive), or another program name (case-sensitive) that you find in the log output.
rsvp
Resource Reservation Protocol (RSVP)
dot1x
IEEE 802.1X Port-Based Access Control
lacp
Link Aggregation Control Protocol (LACP)
stp
Spanning Tree Protocol (STP)
rstp
Rapid Spanning Tree Protocol (RSTP)