34
29/06/2022
EN
LEAK CONTROL
Never use an open flame to check for leaks. Do not check for leaks by smoking.
The gas connections have been tested by the manufacturer to
avoid any risk of leakage.
However, the appliance should be checked regularly for
leaks. Check immediately if you smell gas.
Check the leakage control points :
• 1. gas cylinder valve / regulator
• 2. regulator / hose
• 3. hose / gas inlet of the appliance
Prepare a soap solution with one part dishwashing liquid and
three parts water. The soap solution can be applied with a bott-
le, brush or cloth to check for leaks, as shown in the diagram
opposite. The gas cylinder valve must be in the
OFF
position at
this stage of the test. Once the soapy solution has been applied
to the gas connections, the gas supply valve can be turned to
the
open (ON)
position. If there is a leak, soap bubbles will
form in the applied solution. If there is a leak, turn off the gas supply. Repair the leaking connections, open
the gas supply and carry out a new check.
1
2
3
NOT PROVIDED
LEAKAGE CONTROL
POINTS
1
2
3
29cm
60cm
The space available under the appliance allows for the storage of a 29x60cm gas bottle after use.
Содержание ARCTIC PCG230KD
Страница 8: ...8 29 06 2022...
Страница 70: ...70 29 06 2022 ASSEMBLAGE ENSAMBLAJE ASSEMBLY VERZAMELING MONTAGEM ASSEMBLAGGIO A B C D E F G H I J K L M...
Страница 88: ...88 29 06 2022...
Страница 89: ......