We recommend PE cleaning agents that fulfil the test requirements under
DVGW-VP 603, e.g. AHK cleaning agents.
NOTICE
When using alcoholic cleaning agents, the alcohol percentage must be
at least 99.8% in accordance with DVGWVP 603.
When cleaning, prevent dirt from the unscraped pipe surface from being rubbed
into the fusion zone. For every fusion zone a fresh cleaning paper is to be used.
If necessary, use in case of larger fusion zones several cleaning papers.
The cleaning agent
must have evaporated completely before the fusion
process can take place.
Fig 5
Afterwards, use the FRIALEN marker
to refresh the marks for the fusion
zone width on the pipe. These marks
were removed during scraping and
cleaning (see Fig 5).
The surfaces for joining must be clean
and dry before the fitting is installed.
Avoid touching the cleaned fusion
zone with your hand. Moisture, e.g.
dew or frost on the joining surface,
must be removed with suitable aids.
First remove the fusion fitting from its
packaging directly before it is processed. This packaging protects the fitting
against external effects during transport and storage.