Installation instructions
Installations of the unit into the wall
Alternative method of installation if external
support cannot be provided.
Flash or seal around external
wall frame or architrave
Sturdy timber
frame
Timber framed
wall or partition
Solid timber support
Steadying bracket
(one per side)
Drain pan
Ensure louvres
are entirely
outside the wall
AIR IN
AIR IN
AIR OUT
100mm minimum
OPTION A
AIR IN
LOUVRE
BRICK
WALL
O
45 BRICK CUT AWAY
TO CLEAR LOUVRES
FRONT
AIR OUT
AIR IN
AIR IN
TOP
VIEW
O
45 BRICK CUT AWAY
TO CLEAR LOUVRES
100mm
BRICK
WALL
100mm
OPTION B
MODEL(Btu/h)
BODY DIMENSION(mm)
(W x H x D)
<18000
18000<Model<21000
600x380x527
> 21000
Dimensions
661x427x742
Installation of the unit into the Housing
1. Fit the drain pan to the housing and attach a drain tube to a
suitable location if required.
2. Slide the unit into the housing until it is firmly against the rear
of the housing. Care is required to ensure the foam sealing
strips on the housing remain in position.
3. Engage the chassis fixing brackets into the bottom housing
rail and secure to the base with the screw provided.
4. Install the front panel as per the Installation lnstruction.
5. Connect the air conditioner to the power and position excess
cord length beneath the air conditioner base.
6. Switch unit on. Check for operation of the unit and check for
vibration in the installation.
660x427x645
Minimum norminal cross-sectional area of conductors:
Rated current of appliance
(A)
Nominal cross-sectional area
2
(mm )
0.75
1
1.5
2.5
Suggest Minimum Wire Size
(
AWG:
)
:
American Wire Gage
Appliance Amps
AWG Wire Size
10
13
18
25
18
16
14
12
30
10
>3 and <6
>6 and <10
>10 and <16
>16 and <25