13
LP GAS CONNECTION TO LP PIPED SYSTEMS:
An LP piped system is one with a large central LP tank that feeds the entire household. Those systems
are normally equipped with a high pressure regulator by the large LP tank and low pressure regulators
close to the home.
The gas line connectors must comply with the
Standard for Connectors for Outdoor Gas Appliances
and Manufactured Homes, ANSI Z21.75 • CAS 6.27
, and suitable for outside installation. The maximum
length of the connection shal be 6 Ft. (1.82 m)
GAS CONNECTION
-
NATURAL GAS (NG)
NEVER CONNECT THE PIZZA OVEN TO AN UNREGULATED GAS SUPPLY.
Before proceeding, ensure the oven is fitted for natural gas. Connecting to an improper gas type will re-
sult in poor performance and increased risk of damage or injury.
Total gas consumption (per hour) with all burners set on “HI” is a follows:
Hearth Burner
18,800 BTUH
Log Burner
22,600 BTUH
The installation of this appliance must conform with local codes or, in the absence of local codes, to the
national fuel gas code, ANSI Z223.1a
-
1988. Installation in Canada must be in accordance with the
Standard CAN/ CGA
-
B149.1 Natural Gas Installation or CAN/CGA
-
B149.2, Propane Installation Code.
Manifold pressure with NG:
Operating:
5.0” W.C. (.14 PSI)
Non
-
operating:
5.5” W.C. (.16 PSI)
Optimum pressure:
7.0” W.C. (.25 PSI)
NOTE:
To ensure proper heating performance of this ap-
pliance, verify that the gas line supply pressure is ade-
quate (7.0” W.C. supply pressure is preferred) to maintain
5” W.C. manifold pressure.
Use a minimum 1/2” Ø Flex Hose to prevent gas starva-
tion. Alternatively, use a 1/2” NPT hard gas pipeline.
(
See Figure # 5
)
Ensure that the service pipe supplying the oven is fitted
with a shut off valve conveniently positioned and easily ac-
cessible as an emergency gas shutoff.
Your
Alfresco
™ Pizza Oven for use with Natural Gas
comes equipped with its own regulator which MUST NOT
be removed. If this regulator needs to be replaced use only
the type specified by
Alfresco
™ for this appliance.
SHUT OFF HAND VALVE
MUST BE LOCATED IN
ACCESSIBLE AREA
INCOMING NG
GAS SUPPLY
1/2” Ø
-
NG
FLEXIBLE HOSE
Figure # 5