PROPER USE
The permanent lifting magnet TML 1000 is designed to lift ferromagnetic, metallic loads and may only be
used according to its technical data and determination. Proper use also includes adherence to the
start-up, operating, environment and maintenance conditions specified by the manufacturer. Proper use
and maintenance of the lifting magnet are the responsibility of the user. It is also his responsibility to
understand the Operation Instructions.
DEVICE DESCRIPTION
The TML (Thin Material Lifter) is a switchable lifting magnet with manual actuation for the lifting, transporting
and lowering of ferromagnetic materials. By pressing the lever (F) down, the magnetic field generated by the
permanent magnet can be activated in the lower magnetic plate (C) area.
Thanks to the special design, a very compact magnetic field is generated which develops excellent adhesive
force, especially on thin materials (less than 10 mm). The magnet can be deactivated by first pressing the
safety tab (E) with the heel of the hand and then moving the lever upwards. An adjustable oil damper (G) is
incorporated underneath the safety tab in order to absorb the recoil energy of the lever, especially during
use on thin materials. Additional threads for mounting (H) are located on either front side of the magnet
which, if desired, can be used as holding device. An eyelet (A) is situated on the top of the lifting magnet for
attachment to a crane. The load-bearing capacity of the lifting magnet is equivalent to 1/3 of the maximum
breakaway force of the magnet and thus is equivalent to the standard safety factor 3:1.
A) Load hook
B) Basic body
C) Magnetic contact area
D) Center of the magnet
E) Safety tab
F) Lever for activation/
deactivation
G) Shock absorber for lever
H) Additional threads
for mounting