background image

Seite | 16  

 

 
 
Technical data 

 

 
Model

 

 

 

 

 

alfda® AEF2000 

Recommended room size

 

 

 

20

–30 m² 

Dehumidifaction perfomance

   

 

20 Liter / Day 30°C / 80 %) 

Water tank capacity 

 

 

 

5,5 Liter 

Power supply

 

 

 

 

220-240 V ~ (50 Hz) 

Power consumption 

 

 

 

420 W 

Net-weight

 

 

 

 

14,5 kg 

dimensions

 

 

 

 

Height 550 mm, length 340 mm, width 210 mm 

suitable room temperature 

 

 

5

–32°C 

Refrigerant/ Filling quantity

 

 

 

R290 / 60 g 

 
 
Specifications are subject to change without notice for the purpose of improvement. 
 
 

Problem solving 

 
If  you  have  any  problems,  please  check  the  following  points  before  contacting  our  customer 
service:

 

 

Problem 

Points to check 

Problem solving measure 

 
 
 
No function

 

Is the power cable 
connected? 
 

 

Is the water tank inserted 
correctly? 
 

 

Is the water tank full?

 

Connect the connecting 
cable to the mains supply. 

 

Insert the water tank 
correctly according to the 
instructions. 

 

Entleeren Sie den 
Wassertank. 

 
Dehumidification 
performance is too low 

Is the filter dirty? 
 
Is the AIR-CLEAN operating 
mode running? 

Clean the filter according to 
the instructions.

 

Switch operating mode to 
dehumidification. 

Содержание AEF2000

Страница 1: ...user manual Dehumidifier AEF2000...

Страница 2: ...unpleasant moisture in everyday life and also serves to dry washed laundry indoors It is not suitable for keeping the humidity very low about 50 or less relative humidity in the room The room temperat...

Страница 3: ...t plug the dehumidifier in a plug which electric line is below the dehumidifier The plug must not be damaged oder modified Therefore do not clamp the cable into any doors and do not place hot or heavy...

Страница 4: ...e not exposed to the exhausted air of the dehumidfier Do not use the dehumidfier as a chair or footstool For safety reasons unplug the the device if it wont be used for a longer period of time Hold th...

Страница 5: ...ry gas regulations Work on a refrigerant circuit may only be carried out by persons who have a currently valid certificate from an accredited assessment body to ensure safe handling of refrigerants in...

Страница 6: ...se of the dehumidifier take note of the minimum distances like in the picture IMPORTANT If reception signals from television sets radios etc are disturbed please ensure a minimum distance of 70 cm bet...

Страница 7: ...dicator display Using a humidity sensor your dehumidifier measures the relative humidity in the room shows it on the display and in the form of a three colour indicator display see picture BLUE relati...

Страница 8: ...mode the fan runs at a low level Strong drying Maximum dehumidifaction performance at very high humidity In the heavy drying operating mode the fan runs permanently at maximum speed Clothes drying to...

Страница 9: ...mode will then go out The operating time starts automatically after the desired value has been entered Your dehumidifier stops operation as soon as the specified number of operating hours has been re...

Страница 10: ...ion and Air Clean air cleaning In the Permanent dehumidification operating mode the fan automatically runs at a low speed In the operating modes Heavy drying and Clothes drying the fan automatically r...

Страница 11: ...he filter cassette lightly against the bottom of the unit until it clicks into place You can order the air filter fleece comfortably in the double pack 2 pieces under the article number 159712 in the...

Страница 12: ...s so that the tank is released from the unit Carefully remove the tank from the dehumidifier with both hands so that no water is spilled To carry the tank you can fold out the carrying handle provided...

Страница 13: ...ainage hose instead of water tank Alternatively the water can be led permanently into a floor drain by means of a drainage hose The condensate drain is located on the back of the unit to which you can...

Страница 14: ...ir cleaning mode The circulation of the refrigerant may cause operating noises in the dehumidifier when starting As soon as the circulation is stable the operating noise is also reduced Defrosting Dur...

Страница 15: ...s Cleaning the prefilter recommendation every 2 weeks The dehumidification efficiency of the dehumidifier is reduced when the filter is clogged Remove the rear cover from the unit and remove the filte...

Страница 16: ...pose of improvement Problem solving If you have any problems please check the following points before contacting our customer service Problem Points to check Problem solving measure No function Is the...

Страница 17: ...essary increase the room temperature Your dehumidifier has no technical defect in the following situations Situation Cause Operation stops occasionally The device defrosts Dehumidification performance...

Страница 18: ..._________________________ ________________________________________________________ ________________________________________________________ ________________________________________________________ ___...

Страница 19: ...ce number on the proof of purchase If a return is agreed return the unit securely packaged at your expense to Customer Service Enclose a copy of the proof of purchase on which you note the defect If t...

Страница 20: ...teries from the remote control separately as described below Notes on battery disposal In connection with the sale of batteries or the delivery of devices containing batteries we are obliged to inform...

Отзывы: