Seite | 14
Note: When using the drainage hose, the water tank must be inserted in the unit.
If the permanent drainage by means of a drainage hose is not used, please remove the hose from
the condensate drain. The condensation water is then returned to the water tank.
Signal tone
Each keystroke is confirmed with a signal tone. If there is no beep, make sure your finger is on the
correct symbol on the touch screen.
Hints for use
To protect against frequent switch-on cycles, the compressor is provided with a standstill time of 3
minutes. If, for example, the dehumidification process is interrupted by disconnection from the
mains supply or manual shutdown and the unit is then put back into operation, the compressor will
not restart until the 3-minute shut-off period has elapsed.
The performance of the dehumidifier is also affected by the air outside the room. For efficient
operation, please close all windows and doors in the room.
If the ambient temperature exceeds 36° C, the dehumidification process is stopped for safety
reasons and the unit automatically switches to air cleaning mode.
The circulation of the refrigerant may cause operating noises in the dehumidifier when starting. As
soon as the circulation is stable, the operating noise is also reduced.
Defrosting
-
During defrosting, both the dehumidification function and the air cleaning function are
deactivated. During this procedure, the "Defrost function" indicator lights up on the
display.
-
Do not unplug the appliance during defrosting and do not switch off the appliance.
Operation with an external timer or WLAN socket outlet
The dehumidifier can be switched on and off via a standard external timer or by using a WLAN-
controlled socket. To do this, the device must remain switched on. The dehumidifier then
continues to operate in the same mode and with the same fan speed that was set during previous
operation (automatic restart-function).
If you do not use the device for an extended period of time
1. Disconnect the device from the mains by pulling the mains plug and bundle the mains cable
properly to avoid damage.
2.
Empty the water tank and dry it with a soft cloth. Replace the tank in the dehumidifier.
3. Clean the prefilter and, if necessary, remove the dirty air filter fleece.
4. Store the unit upright in a well-ventilated place (standing - never lying) and avoid direct sunlight.