background image

Seite | 14  

 

Note: When using the drainage hose, the water tank must be inserted in the unit. 
If the permanent drainage by means of a drainage hose is not used, please remove the hose from 
the condensate drain. The condensation water is then returned to the water tank. 

 
Signal tone 

 
Each keystroke is confirmed with a signal tone. If there is no beep, make sure your finger is on the 
correct symbol on the touch screen. 
 

Hints for use 

 
To protect against frequent switch-on cycles, the compressor is provided with a standstill time of 3 
minutes. If, for example, the dehumidification process is interrupted by disconnection from the 
mains supply or manual shutdown and the unit is then put back into operation, the compressor will 
not restart until the 3-minute shut-off period has elapsed. 
 
The  performance  of  the  dehumidifier  is  also  affected  by  the  air  outside  the  room.  For  efficient 
operation, please close all windows and doors in the room. 
 
If  the  ambient  temperature  exceeds  36°  C,  the  dehumidification  process  is  stopped  for  safety 
reasons and the unit automatically switches to air cleaning mode. 
 
The circulation of the refrigerant may cause operating noises in the dehumidifier when starting. As 
soon as the circulation is stable, the operating noise is also reduced. 
 

Defrosting 

-

 

During  defrosting,  both  the  dehumidification  function  and  the  air  cleaning  function  are 
deactivated.  During  this  procedure,  the  "Defrost  function"  indicator          lights  up  on  the 
display. 

-

 

Do not unplug the appliance during defrosting and do not switch off the appliance. 

 
 

Operation with an external timer or WLAN socket outlet 

The  dehumidifier  can  be switched  on  and  off via  a  standard  external  timer  or  by  using  a  WLAN-
controlled  socket.  To  do  this,  the  device  must  remain  switched  on.  The  dehumidifier  then 
continues to operate in the same mode and with the same fan speed that was set during previous 
operation (automatic restart-function). 
 

If you do not use the device for an extended period of time 

1.  Disconnect  the  device  from  the  mains  by  pulling  the  mains  plug  and  bundle  the  mains  cable                                                                                           
properly to avoid damage. 
2.

 

Empty the water tank and dry it with a soft cloth. Replace the tank in the dehumidifier. 

3. Clean the prefilter and, if necessary, remove the dirty air filter fleece.  
4. Store the unit upright in a well-ventilated place (standing - never lying) and avoid direct sunlight. 

 
 

Содержание AEF2000

Страница 1: ...user manual Dehumidifier AEF2000...

Страница 2: ...unpleasant moisture in everyday life and also serves to dry washed laundry indoors It is not suitable for keeping the humidity very low about 50 or less relative humidity in the room The room temperat...

Страница 3: ...t plug the dehumidifier in a plug which electric line is below the dehumidifier The plug must not be damaged oder modified Therefore do not clamp the cable into any doors and do not place hot or heavy...

Страница 4: ...e not exposed to the exhausted air of the dehumidfier Do not use the dehumidfier as a chair or footstool For safety reasons unplug the the device if it wont be used for a longer period of time Hold th...

Страница 5: ...ry gas regulations Work on a refrigerant circuit may only be carried out by persons who have a currently valid certificate from an accredited assessment body to ensure safe handling of refrigerants in...

Страница 6: ...se of the dehumidifier take note of the minimum distances like in the picture IMPORTANT If reception signals from television sets radios etc are disturbed please ensure a minimum distance of 70 cm bet...

Страница 7: ...dicator display Using a humidity sensor your dehumidifier measures the relative humidity in the room shows it on the display and in the form of a three colour indicator display see picture BLUE relati...

Страница 8: ...mode the fan runs at a low level Strong drying Maximum dehumidifaction performance at very high humidity In the heavy drying operating mode the fan runs permanently at maximum speed Clothes drying to...

Страница 9: ...mode will then go out The operating time starts automatically after the desired value has been entered Your dehumidifier stops operation as soon as the specified number of operating hours has been re...

Страница 10: ...ion and Air Clean air cleaning In the Permanent dehumidification operating mode the fan automatically runs at a low speed In the operating modes Heavy drying and Clothes drying the fan automatically r...

Страница 11: ...he filter cassette lightly against the bottom of the unit until it clicks into place You can order the air filter fleece comfortably in the double pack 2 pieces under the article number 159712 in the...

Страница 12: ...s so that the tank is released from the unit Carefully remove the tank from the dehumidifier with both hands so that no water is spilled To carry the tank you can fold out the carrying handle provided...

Страница 13: ...ainage hose instead of water tank Alternatively the water can be led permanently into a floor drain by means of a drainage hose The condensate drain is located on the back of the unit to which you can...

Страница 14: ...ir cleaning mode The circulation of the refrigerant may cause operating noises in the dehumidifier when starting As soon as the circulation is stable the operating noise is also reduced Defrosting Dur...

Страница 15: ...s Cleaning the prefilter recommendation every 2 weeks The dehumidification efficiency of the dehumidifier is reduced when the filter is clogged Remove the rear cover from the unit and remove the filte...

Страница 16: ...pose of improvement Problem solving If you have any problems please check the following points before contacting our customer service Problem Points to check Problem solving measure No function Is the...

Страница 17: ...essary increase the room temperature Your dehumidifier has no technical defect in the following situations Situation Cause Operation stops occasionally The device defrosts Dehumidification performance...

Страница 18: ..._________________________ ________________________________________________________ ________________________________________________________ ________________________________________________________ ___...

Страница 19: ...ce number on the proof of purchase If a return is agreed return the unit securely packaged at your expense to Customer Service Enclose a copy of the proof of purchase on which you note the defect If t...

Страница 20: ...teries from the remote control separately as described below Notes on battery disposal In connection with the sale of batteries or the delivery of devices containing batteries we are obliged to inform...

Отзывы: