![alfaplam GRANDE Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/alfaplam/grande/grande_instruction-for-use-and-installation-instructions_2895602018.webp)
18
9.5 DESCRIPTION OF THE MESSAGE IN DISPLAY
Messages and
indications in the
display
Meaning of the message and the status of the boiler
The boiler is at rest
The boiler is at rest, but time mode is activated, so that it turns on automatically
at preset time
The boiler checks if there is a flame and burning in the
firebox
.
This process is
activated after power failure
In ignition stage, after screw conveyor has filled firebox, ignition spark plug
heats the pellets to ignition
After Heat up phase, the boiler ignites pellets. There is not dosing at this stage.
At the end of ignition phase boiler turns off the spark plug and examine whether
ignition is successful ,whether burning is proper and whether the temperature
rises properly
Burning phase (which is usually the working phase).
The lower display shows the temperature of the flue gas at the outlet of the
boiler.
Combustion phase, the lower indicator (display) displays the temperature of the
water in the boiler
Combustion phase, the lower indicator (display) displays the temperature of the
water in the return line
Burning phase, the upper indicator (display) displays the current power of the
boiler (Px) and the set power of the boiler (Dx)
Stages of cleaning. Fans are blowing ash and other residues from the firebox.
This phase occasionally runs automatically in the process of burning.
The boiler is in the process of stopping and cooling.
When the water temperature reaches a certain temperature, even with minimum
temperature, the boiler switches to COOL FLUID stage and begins to cool.
Boiler automatically restarts after the water in the boiler is cooled below a
certain value.
Содержание GRANDE
Страница 31: ...31 16 0 DIMENSIONS OF BOILER GRANDE Figure 17 ...