4.0 FIRST BOILER STURT-UP
Instructions for safety of people, animals and personal property
The task is to make the installer familiarized with simple guidelines that should be followed in order that the pellet
boiler could be installed correctly.
In addition to the required standards, it is necessary to read the remainder of the instructions for use, maintenance
and installation to get as much information as possible.
-
connect pellet boiler to the power grid
-
do not let children and animals come close to the pellet boiler
-
use only good quality pellet (do not use other types of fuel)
-
inform users about the possible risks and dangers and train them in handling of pellet boilers
-
if the pellet boiler should be installed on the wooden floor, insulation is recommended
Pellet boiler operates so that underpressure is created in the combustion chamber, thus it is important to be
sure that
thermal tightness
of flue gas pipe is provided.
Condensing of boiler at first start-up is normal.
When the pellet boiler is put into operation for the first time, the paint in which it is painted evaporates.
Therefore it is necessary to ventilate the space. (This results from the stabilization process in painting)
5.0 WARNINGS ABOUT SAFETY IN TECHNICAL MAINTENANCE
Before taking into account the safety regulations, the repair service shall:
always use safety devices and individual devices according to Directive 89/391/EEC
turn off electrical supply before commencing any activity
use only the appropriate tool
prior to any work to the boiler it is necessary to be sure that the boiler and ash in it are cold
-
THE BOILER SHOULD NOT BE USED IF ANY SAFETY DEVICE IS FAULTY, IMPROPERLY
REPAIRED OR IS NOT WORKING!!
-
do not make any repairs of any type for any reason, except as permitted or approved by an authorized
person
-
always use original spare parts. Do not allow the particular part of the boiler to worn out before the same is
replaced. Timely replacement of the boiler part prevents possible damages due to the sudden failure of its
components, which may seriously endanger people and / or their characteristics
-
clean the pan-ashtray before each use
-
check possible formation of condensation which alerts us of the presence of water infiltration and the
formation of condensation due to cooling of flue gases
-
determine the cause of condensation and prevent further condensation to establish proper operation of
pellet boilers.
5.1 SAFETY WARNING FOR USERS
The room in which the pellet boiler is located (installation area), must be in accordance with local, national and
European directives.
Pellet boiler is a heating device with certain external surfaces that are relatively hot during its work.
Pellet boiler is used for heating by wood pellets (pellets 6 mm in diameter and up to 30 mm in length, with a
maximum humidity of up to 10%).
When using the device it is recommended
:
NOT to approach the boiler and touch the glass of the door of firebox, because there is a risk of burning
N OT to touch connection to the chimney, because there is a risk of burns
NOT to perform any cleaning of the device
NOT to open the fire door at the time of its work as the boiler works properly only if the firebox
door is fully tightened
NOT to clean the ashes when the boiler is operating