TECHNICAL DATA
HEATING POWER:
Rated heating power (wood/coal)
18,4 kW/ 19,9 kW
Heating power of stove emission (wood/coal)
5,4 kW/ 5,8 kW
Thermal power of delivered water (wood/coal)
13 kW/14,1 kW
REQUIRED FLUE DRAFT
20 Pa
DIAMETER OF FLUE EXTENSION
150 mm
HEIGHT FROM FLOOR TO AXIS OF FLUE EXTENSION
635 mm
STOVE DIMENSIONS:
Width
365 mm
Height
850 mm
Depth
600 mm
CONNECTIONS OF DISCHARGE AND RETURN LINE
R5/4
″
RS
CONNECTIONS OF THERMO VALVE AND SAFETY VALVE
R1/2
″
RU
CONNECTIONS OF COOLING PIPES
R1/2
″
RS
BOILER VOLUME
16 (l)
HEATING VOLUME (wood/coal)
276 – 460 / 296 - 497m
3
Heating volume of stove emission (wood/coal)
81 – 135 / 87 - 145m
3
Heating volume of hot water (radiators) (wood/coal)
125 – 195 / 211 - 352m
3
MAXIMAL OPERATING PRESSURE
1,9 bar
MAXIMAL OPERATING TEMPERATURE
90
°
C
WEIGHT (gross/net)
140/153 kg
FLUE GAS TEMPERATURE (wood/coal)
335 / 345
°
C
CONTENT OF CO (13% O2)
0,45 / 0,36 %
ENERGY EFFICIENCY
72 / 74 %
NOTE
With its aesthetic design, solid fuel furnace type 23 fits perfectly in any kitchen ambient and in the rest of the
household. It could be used for heating both apartments and houses.
These furnaces – stoves have a built- in coil (copper pipe) connected to the thermoregulation valve (Fig. 9, pos.
13), that works as a safety thermostat and keeps from overheating the furnace – stove.
Installation of the thermoregulation valve into closed central heating system is MANDATORY.
In case of an open central heating system, installation of the thermoregulation valve is not mandatory.
In order for a furnace to work properly, follow this instructions manual carefully.