![Alfa Laval Toftejorg SaniMicro Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/alfa-laval/toftejorg-sanimicro/toftejorg-sanimicro_instruction-manual_2895114012.webp)
4 Installation
4.3
General safety and installation instructions
4100-0009
Self draining position
Important
information:
Recommended installation position:
The Rotary Spray Head tank cleaning machine should be installed in vertical position (upright or upside
down). If the machine is installed horizontally, the life time may be reduced.
It is recommended to install a filter with mesh size 250 µm (0.01”) in the supply line to avoid particles, scale etc. from clogging
the inside of the Rotary Spray Head.
Before installation, all supply lines and valves must be thoroughly flushed to remove remains from welding, grinding
dust, scale and other foreign matter. During handling and installation treat the machine with care in order not to damage the
fine surface of the machine.
NOTE
The machine shall be installed in accordance with national regulations for safety and other relevant regulations and standards. In
EU-countries the complete system must fulfil the EU-machine Directive and depending of application, the EU-Pressure Equipment
Directive, the EU-ATEX/IECEx Directive and other relevant Directives and shall be CE-marked before it is set into operation.
Warning:
Precautions shall be made to prevent starting the cleaning operation, while personnel are inside the tank
or otherwise can be hit by water jets from the cleaner head.
For information on use in potential explosive atmospheres see paragraph 4.4 Specific conditions for safe use in accordance
with ATEX/IECEx certification page 13.