Instruction Manual, Alfa Laval Toftejorg SaniJet 25
Standard machines, machines delivered with Q-Doc and/or ATEX certification, Dir. 94/9/EC
IM-TE91A760_EN12
Assembly of lower parts
11. Screw the bevel gear (Pos. 14) with the hub tool (TE20J392) while pressing on the tool
Tighten the bevel gear (Pos. 14) using Ring key (TE81B159) until you feel a stop and then
tighten it a bit more. The stop you feel is two surfaces connecting.
12. Check that the hub nut (Pos. 15) can rotate freely and that O-rings inside are mounted
correctly (Pos. 16 and 17).