Special Conditions for Safe Use – ATEX
Instruction Manual, Alfa Laval Toftejorg SaniJet 25
Standard machines, machines delivered with Q-Doc and/or ATEX certification, Dir. 94/9/EC
IM-TE91A760_EN12
Page 17
Special Conditions for Safe Use – ATEX
In Acc. with the ATEX Certification, Directive 94/9/EC the following special conditions shall be obeyed.
ATEX
Warning:
The unit may be operated, in a hazardous area, only when filled with the process fluid.
ATEX
Warning:
Working temperature max:
The maximum permitted process fluid temperature and ambient temperature
when the machine is operating is 95°C.
Ambient temperature:
When the machine is
not
operating, the maximum permitted ambient
temperature is 140°C.
ATEX
Warning:
The maximum permitted process fluid working pressure is 8 bar.
ATEX
Warning:
The unit must not be operated in a vessel having an enclosed volume of greater than
100m
3
.
Tanks larger than 100 m
³
:
To use Tank Cleaning Machines in tanks larger than 100m
³
is possible under certain
conditions.
It is necessary to know the current factors such as tank size, cleaning solvent and
product.
Additives can be used in the cleaning solvent, or, for example, the tank can be filled with
nitrogen. The basic rules are described in the guide "CLC / TR 50404:2003“.
Following a guidance document such as "CLC / TR 50404:2003“ to establish safe use of
machinery and process is the users own responsibility and is not covered by the ATEX
certification for this product.
In addition to the above mentioned precautions relating to the ATEX guidelines Directive
94/9/EC of March 23 1994, the general safety precautions, page 22, must be observed.