8
Mount the remaining locking bolts and check
measurement
A
on both sides, top and
bottom.
9
Mount protection sheets (if provided).
10
Connect pipes.
11
If the heat exchanger does not seal when
measurement A has been reached, it can be
tightened further to
A
minus 1.0%.
6.5 Closing - TL15
Follow the instructions below to ensure that the heat exchanger will be properly closed.
For bolt identification, refer to
1
Check that all the sealing surfaces are clean.
2
Brush the threads of the bolts clean, using a
steel wire brush or the Alfa Laval thread
cleaner. Lubricate the threads with a thin
layer of grease, e.g. Gleitmo 800 or its
equivalent.
3
Attach the gaskets to the plates or check that
all gaskets are properly attached. Check that
all gaskets are correctly positioned in the
grooves.
NOTE
If the gasket is wrongly positioned, it will
show by the fact that it rises out of the
gasket groove or that it is positioned
outside the groove.
200000418-2-EN-GB
40
6 Maintenance
EN
Содержание Industrial Series