4 Installation
Step 4
Lift off the control head and be aware that the 4 O-rings (E) remain
in the grooves.
2109-0032
E
E
Step 5
Turn the control head 180 degrees and check that the marking (F)
is aligned with the NO symbol.
2109-0033
F
Step 6
Re-attach the control head to the actuator by tightening the 4
screws (G) with a tightening torque of 2Nm.
2109-0034
G
G
Step 7
Reconnect the air supply and re-power the Unique Control to
complete the change.
See Step 3 and Step 5 in chapter 4 Installation for details.
Step 3
Step 5
2109-0010
2109-0012
18
Содержание ESE02126-EN
Страница 1: ...Instruction Manual Unique Control for Butterfly Valves 2109 0039 ESE02126 EN 2012 02 Original manual ...
Страница 2: ......
Страница 23: ...7 Parts list 7 1 Parts list 2109 0007 C 12 1 D D B A 13 2 11 23 ...
Страница 25: ...25 ...