4 Installation
4.7
Calibration- step 5
Step 1
Prerequisite
The Unique Control must be fully installed:
-
Mechanically
-
Pneumatically
-
Electrically
The unit will flash green, when ready to calibrate the first time.
Calibrate
Push the blue button (N) on the sensor unit until you see a yellow
flash.
The Unique Control will automatically calibrate.
The unit is ready to use when the green light comes back on.
2109-0027
N
Step 2
Put the prism/top cover back on by pushing it down when the
mark on the prism (J) and the open padlock (K) are aligned.
Then turn it clockwise towards the closed padlock (L) to secure
the top.
2109-0040
K
J
L
Operating LED feedback
Actuator status
LED feedback
De-energised
Green
Energised
Yellow
Pressure alarm (De-energised)
Red/green flashing
Pressure alarm (Energised)
Red/yellow flashing