4 Installation
4.6
Connecting the communication cable- step 4
Step 1
Remove the prism/top cover by turning the prism/top cover
counter-clockwise.
When the mark on the prism (J) is aligned with the open padlock
symbol (K), the prism/top cover can be lifted off.
2109-0028
K
J
Step 2
Install the cable in the cable gland (M).
NOTE!
Cable connection:
Main cable gland: PG9 (ø4-ø8 mm)
Max. wire diameter: 1.0 mm
2
(AWG 18).
If the cable gland comes loose from the control head during
installation, it must be secured with a tightening torque of 4 Nm.
2109-0023
M